MORRILTON, AR —
OSHA Inspection: SEMCO, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SEMCO, INC. in #3 INDUSTRIAL PARK DR., MORRILTON, AR 72110 (NAICS 332322). OSHA activity number 339524100.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEMCO, INC.
- Site address
- #3 INDUSTRIAL PARK DR.
- City
- MORRILTON
- State
- AR
- ZIP
- 72110
- Mailing
- #3 INDUSTRIAL PARK DR., MORRILTON, AR 72110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 31
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.252 B02 III
- Issued
- Apr 17, 2014
- Abate by
- Apr 21, 2014
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: The welding area of the SEMCO, Inc. Morrilton, Arkansas facility had welders exposing employees to eye injuries while welding without welding screens.
Recent events (1)
- — Z (S) $4000
1910.305 H07
- Issued
- Apr 17, 2014
- Abate by
- Apr 21, 2014
- Penalty
- Initial $5,000 · Current $5,000
General-duty citation text
29 CFR 1910.305(h)(7): Splices. Portable cables may not be operated with splices unless the splices are of the permanent molded, vulcanized, or other approved type. At or near the equipment test station #1 at the SEMCO, Inc., Morrilton, Arkansas facility, employee were exposed to electrical shock hazards from an electrical extension that used electrical components at all four test stations.
Recent events (1)
- — Z (S) $5000
1910.1200 H03 IV
- Issued
- Apr 17, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: On or about December 17th, 2014 at the SEMCO, Inc. Morrilton, Arkansas facility the Hazardous Communication Program did not include training on the SDS format and the new label elements.
Recent events (1)
- — Z (O) $0
More inspections at Semco, INC.
View Semco, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339524100.