ATHENS, AL ·
OSHA Inspection: BARKSDALE DENTAL LABORATORY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BARKSDALE DENTAL LABORATORY, INC. in 206 COMMERCIAL DRIVE, ATHENS, AL 35611 (NAICS 339116). OSHA activity number 339526139.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BARKSDALE DENTAL LABORATORY, INC.
- Site address
- 206 COMMERCIAL DRIVE
- City
- ATHENS
- State
- AL
- ZIP
- 35611
- Mailing
- 201 FINNEY DRIVE SW, HUNTSVILLE, AL 35824
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339116
- Employees
- 50
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.37 B02
- Issued
- Apr 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) On or about 12/17/2013 - West exit door, the exit sign was blocked from sight by cabinets on the north side of the hallway.
Recent events (1)
- · Z (O) $0
1910.157 C01
- Issued
- Apr 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about 12/17/2013 - Hallway, adjacent to drinking fountain, a portable fire extinguisher was not mounted and identified.
Recent events (1)
- · Z (O) $0
1910.157 E03
- Issued
- Apr 10, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: a) On or about 12/17/2013 - Contour and casting department, a portable fire extinguisher was not subjected to an annual maintenance check. b) On or about 12/17/2013 - Hallway, adjacent to drinking fountain, a portable fire extinguisher was not subjected to an annual maintenance check.
Recent events (1)
- · Z (O) $0
1910.1030 C01 IV
- Issued
- Apr 10, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually: a) On or about 12/17/2013 - Model and die department, the employer had not reviewed and updated the Exposure Control Plan for employees working with dental impressions.
Recent events (1)
- · Z (O) $0
1910.1030 C01 IV B
- Issued
- Apr 10, 2014
- Abate by
- May 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(c)(1)(iv)(B): The review and update of the exposure control plan did not document annually consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure: a) On or about 12/17/2013 - Model and die department, the employer had not documented annual consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure for employees working with dental impressions.
Recent events (1)
- · Z (O) $0
1910.1030 G02 I
- Issued
- Apr 10, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(g)(2)(i): The employer did not ensure that each employee with occupational exposure participated in a training program: a) On or about 12/17/2013 - Model and die department, the employer did not ensure each employee working with dental impressions participated in a training program.
Recent events (3)
- · I $5250
- · Z $10500
- · Z (O) $0
1910.1200 H01
- Issued
- Apr 10, 2014
- Abate by
- May 15, 2014
- Penalty
- Initial $0 · Current $0
90109130A201
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) On or about 12/17/2013 - Facility, employees were not provided effective information and training on materials such as, but not limited to Aluminum Oxide, Cera-Fma, and Cavicide.
Recent events (3)
- · I $5250
- · Z $10500
- · Z (O) $0
More inspections at Barksdale Dental Laboratory, INC.
View Barksdale Dental Laboratory, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339116)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339526139.