WASHINGTON, DC —
OSHA Inspection: J. BARBA CONSTRUCTION, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J. BARBA CONSTRUCTION, INC. in 1329 JEFFERSON ST., NW, WASHINGTON, DC 20009 (NAICS 236118). OSHA activity number 339526147.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J. BARBA CONSTRUCTION, INC.
- Site address
- 1329 JEFFERSON ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 22424 STABLEHOUSE RD., POTOMAC FALLS, VA 20165
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.304 F
- Issued
- Dec 30, 2013
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.304(f): Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery: a) Front Yard - On or about 08/02/2013, Employees were exposed to amputation hazards from use a portable table saw that was missing the following requirements: - Hood with which to protect a carpenter from accidentally contacting the saws rotating blade while ripping wood trim, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(a). - Spreader with which to protect carpenters wood trim and other materials fed into the saw from binding and being ejected, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(b). - A restart switch that would prevent the saw from unexpectedly restarting after a temporary interruption of power, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 3.1.3(c).
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1926.451 G01
- Issued
- Dec 30, 2013
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Front Yard - On or about 08/02/2013, a carpenter on the platform of a ladder jack scaffold was not provided with fall protection and exposed to a 16 foot fall to the ground below.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.501 B13
- Issued
- Dec 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Front Yard, Roof - On or about 08/02/2013, two carpenter whom were crossing a low-sloped roof in order to reach their work area were exposed to a 11 foot fall and had not been provided with fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Dec 30, 2013
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a) Front Yard - On or about 08/02/2013, Two carpenters were exposed to an 11 foot fall from the top of an aluminum extension ladder which was not secured in place and provided with a grab rail and only extended 18 inches above the ladder landing.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1926.404 B01 I
- Issued
- Dec 30, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) Front Yard - On or about 08/02/2013, two carpenters were exposed to a 120 volt electrical shock hazard while using a portable table saw which was not provided with either assured equipment grounding conductor program or ground fault circuit interrupter circuitry.
Recent events (2)
- — I (O) $0
- — Z (O) $0