WASHINGTON, DC ·
OSHA Inspection: PROMPT RESTORATIONS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PROMPT RESTORATIONS INC. in 1918 14TH STREET SE, WASHINGTON, DC 20020 (NAICS 445110). OSHA activity number 339527681.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PROMPT RESTORATIONS INC.
- Site address
- 1918 14TH STREET SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20020
- Mailing
- 6675 BUSINESS PKWY SUITE D, ELKRIDGE, MD 21075
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 445110
- Employees
- 20
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B10
- Issued
- Mar 7, 2014
- Abate by
- Mar 13, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems or a combination of warning line system and safety monitoring system. a) Front Top, Right Side of Structure - Worker on roof's edge laying 4'x8' sheets of insulation was not protected from falling approximately 25' to the concrete below, on or about 12/19/2013. b) Front Top, Left Side of Structure - Worker throwing scrap material and debris from the roof's edge to the ground was not protected from falling approximately 25' to the concrete below, on or about 12/19/2013. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- · Z (S) $2800