SEAFORD, NY ·
OSHA Inspection: A K G 2, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A K G 2, INC. in 3670 OCEAN AVE., SEAFORD, NY 11783 (NAICS 238130). OSHA activity number 339530396.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A K G 2, INC.
- Site address
- 3670 OCEAN AVE.
- City
- SEAFORD
- State
- NY
- ZIP
- 11783
- Mailing
- 122 S 11TH ST, LINDENHURST, NY 11757
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.95 A
- Issued
- Apr 24, 2014
- Penalty
- Initial $1,200 · Current $700 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) Worksite, 3670 Ocean Ave., Seaford - Employees using a pneumatic nail gun for framing were not using eye protection; on or about 12/20/2013. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- · I (S) $700
- · Z (S) $1200
1926.100 A
- Issued
- Apr 24, 2014
- Penalty
- Initial $1,320 · Current $700 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 3670 Ocen Ave., Seaford - Employees getting materials directly under ongoing framing were not wearing ead protection; on or about 12/20/2013. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- · I (S) $700
- · Z (S) $1320
1926.501 B13
- Issued
- Apr 24, 2014
- Abate by
- Apr 30, 2014
- Penalty
- Initial $2,200 · Current $700 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 3670 Ocean Ave., Seaford- Employees framing a house approximately 14 feet above the ground were not protected from falling; on or about 12/20/2013. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
- · I (S) $700
- · Z (S) $2200
1926.1052 C01 II
- Issued
- Apr 24, 2014
- Penalty
- Initial $1,760 · Current $900 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge: a) Worksite, 3670 Ocen Ave., Seaford - Employees using a staircase without a stairrail on the unprotected side to access the top of the 1st floor frame; on or about 12/20/2013. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
- · I (S) $900
- · Z (S) $1760
More inspections at A K G 2, INC.
View A K G 2, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339530396.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.