SELINSGROVE, PA ·
OSHA Inspection: W.D. FOX TAPPING & WELDING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of W.D. FOX TAPPING & WELDING, INC. in 1692 NORTH SUSQUEHANNA TRAIL, SELINSGROVE, PA 17870 (NAICS 237110). OSHA activity number 339531055.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- W.D. FOX TAPPING & WELDING, INC.
- Site address
- 1692 NORTH SUSQUEHANNA TRAIL
- City
- SELINSGROVE
- State
- PA
- ZIP
- 17870
- Mailing
- 955 COOL CREEK ROAD, WRIGHTSVILLE, PA 17368
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.652 A01
- Issued
- Jan 17, 2014
- Abate by
- Jan 30, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) 1692 North Susquehanna Trail, Selinsgrove, PA; Employees were installing a 12 inch water main stop fitting in a 5 foot 8 inch excavation without the use of cave-in protection, on or about 12/23/2013. Abatement Certification and Documentation Required
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1926.1053 B01
- Issued
- Jan 17, 2014
- Abate by
- Jan 30, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 1692 North Susquehanna Trail, Selinsgrove, PA; Employees were using an unknown extension ladder that was not 3 feet above the landing to access and egress a 5 feet 8 inch deep excavation, on or about 12/23/2013. Abatement Certification Required
Recent events (2)
- · I (S) $600
- · Z (S) $1200
More inspections in this industry (NAICS 237110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339531055.