OSHA Inspection: PINSON VALLEY HEAT TREATING COMPANY, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of PINSON VALLEY HEAT TREATING COMPANY, INC. in 6179 SUNRISE DRIVE, PINSON, AL 35126 (NAICS 332811). OSHA activity number 339531188.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pinson Valley Heat Treating Company, INC. — free Get an email when a new federal OSHA severe-injury report for Pinson Valley Heat Treating Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6179 SUNRISE DRIVE
City
PINSON
State
AL
ZIP
35126
Mailing
P.O. BOX 1299, PINSON, AL 35126
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
48
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 4 exposed
Issued
Apr 30, 2014
Abate by
May 27, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
OSH ACT of 1970 Section (5)(a)(1): of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to explosion hazards:     a) On or about 12/21/2013 - Parker building, employees were exposed to an explosion hazard while responding to an emergency situation that occurred on the Allcase A4 endothermic gas furnace.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.132 A

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 30, 2014
Abate by
May 12, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a) On or about 12/21/2012 - Parker Building, employees were not wearing gloves, safety glasses, face shields, hard hats, and flame retardant clothing while loading and unloading the Allcase A4 endothermic gas furnace, S/N#BC-44447, or when responding to emergency situations.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.132 D01 I

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Apr 30, 2014
Abate by
May 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment (PPE) that would protect the affected employee(s) from the hazards identified in the hazard assessment:   a) On or about 12/21/2014 - Parker building, the employer did not ensure employees were wearing the required PPE while loading and unloading furnaces or when responding to emergency situations for equipment such as, but not limited to, the Allcase A4 endothermic gas furnace, S/N#BC-44447.  Employees were not protected from burns by the use of personal protective equipment such as, gloves, safety glasses, face shields, and hard hats.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Pinson Valley Heat Treating Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339531188.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.