PEABODY, MA ·
OSHA Inspection: PINTO RECYCLING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PINTO RECYCLING, INC. in 147 SUMMIT STREET, BUILDING 3D, PEABODY, MA 01960 (NAICS 423930). OSHA activity number 339531832.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PINTO RECYCLING, INC.
- Site address
- 147 SUMMIT STREET, BUILDING 3D
- City
- PEABODY
- State
- MA
- ZIP
- 01960
- Mailing
- 147 SUMMIT STREET, BUILDING 3D, PEABODY, MA 01960
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 L01 II
- Issued
- Apr 4, 2014
- Abate by
- May 21, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck. Location: Facility On or about 12/23/13, the employer did not perform initial training or ensure that each operator successfully completed the training prior to permitting employees to operate the forklift.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.178 L04 III
- Issued
- Apr 4, 2014
- Abate by
- May 21, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: Location: Facility On or about 12/23/13, the employer did not re-evaluate the powered industrial truck operators performance every three years.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 P01
- Issued
- Apr 4, 2014
- Abate by
- May 21, 2014
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): Location: Facility On or about 12/23/13, the employer allowed operators to continue operating the Nissan, model #CPF02A25V powered industrial truck with no rubber gas pedal pad, no horn, no back-up alarm, and the ignition key broken inside of the ignition switch.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.219 D01
- Issued
- Apr 4, 2014
- Abate by
- May 21, 2014
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Location: Facility On or about 12/23/13, the employer did not guard the belt and pulley of the air compressor to protect employees from in-going nip-points.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.303 G01
- Issued
- Apr 4, 2014
- Abate by
- May 21, 2014
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Location: Facility On or about 12/23/13, access to the employer's electrical cabinets was blocked and not readily accessible, due to scrap metal, wheels, and a truck cab placed in front of them.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
More inspections at Pinto Recycling, INC.