OSHA Inspection: LIKA REALTY CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LIKA REALTY CORPORATION in 171 METROPOLITAN AVE, BROOKLYN, NY 11249 (NAICS 531110). OSHA activity number 339531949.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lika Realty Corporation for free Get an email when a new federal OSHA severe-injury report for Lika Realty Corporation is published. One employer, no account, unsubscribe in one click.
Site address
171 METROPOLITAN AVE
City
BROOKLYN
State
NY
ZIP
11249
Mailing
171 METROPOLITAN AVE, BROOKLYN, NY 11249
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
531110
Employees
4
Ownership type
A

12 citations on file for this inspection.

1926.25 A

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 27, 2013
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures:  On December 24, 2013, about 1000, lower level rear of building.  (a)Employer did not ensure demolition and construction debris was removed from the building daily. The large pile of debris cluttered the walkways and work space of the first floor. Stacks of tools and materials in every room on the first floor created an unsafe working condition.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $1200

1926.404 B01 I

Serious Gravity 10 2 instances 4 exposed
Issued
Dec 27, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  Location: On December 24, 2013, at 171 Metropolitan Ave, Brooklyn, on first floor rear of structure.  (a)Employees were using temorpary flexible extension cords to energize electric power tools, radio and cell phone charging station. The power strip utilized was plugged into an extension cord which was not protected by proper ground fault circuit interrupter.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2800

1926.405 A02 II E

Serious Gravity 10 6 instances 4 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(E): All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.  Throughout the first floor and cellar area of the project, 171 Metropolitan Ave, Brooklyn, NY  a). Employees were working within a Gut/Rehab project utilizing temporary lighting to illuminate the work site, the lights were not protected against accidential contact or breaking by a cage system around the bulb.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.405 A02 II F

Serious Gravity 10 6 instances 4 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(F): Temporary lights shall not be suspended by their electric cords unless cords and lights are designed for this means of suspension.  Location: 171 Metropolitan Ave, Brooklyn, Throughout first and basement levels of project.  a). Employees were conducting Gut/Rehab work to interior of project. Employees were exposed to electric shock hazards by the temporary lighting hanging from its own wires, this type of lighting was not designed for self hanging conditions.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.502 B11

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.502(b)(11): When guardrail systems are used at holes, they shall be erected on all unprotected sides or edges of the hole.  Location: Rear of structure, 171 Metropolitan Ave, Brooklyn, NY  a). Employees were working in close proximity (within 5 feet) of an 8 foot deep, 12 foot long, 4 foot wide excavation at the rear of the property.  NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2400

1926.651 I02 IV

Serious Gravity 10 3 instances 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(i)(2)(iv): A registered professional engineer has approved the determination that such excavation work will not pose a hazard to employees.  Location 171 Metropolitan Ave, Brooklyn, basement level of the project.  a). Employees had excavated outside the rear wall of the basement of the structure. Had removed several cubic yards of earth and began erecting a concrete block wall at perimeter rear wall.  There was no engineer approved plans or written description of hte work being performed.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.651 I03

Serious Gravity 10 3 instances 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(i)(3): Sidewalks, pavements and appurtenant structure shall not be undermined unless a support system or another method of protection is provided to protect employees from the possible collapse of such structures.  Location 171 Metropolitan Ave, Brooklyn, NY Rear basement level of project.  a). Employees had removed existing perimeter basement wall construction and rebuilt with hollow concrete block. No indication of a support system and another method of protection was observed, to protect employees from possible collapse of earth or structure.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.651 J02

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  Location; 171 Metropolitan Ave, Brooklyn, NY, rear exterior of basement wall.  (a) Employees had excavated the rear exterior wall of the basment and piled the spoils from the excavation on the sidewalk immediately adjacent to the excavation. The Spoil pile was within 3 inches of excavation and was falling back into the hole during removal of the dirt pile.   NOTE:  BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.651 K01

Serious Gravity 10 3 instances 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(1): Employer did not ensure daily inspections of excavations, the adjacent areas, and protective systems were made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.  Employer did not ensure the inspection was conducted by a competent person prior to the start of work and as needed throughout the shift. Inspections were not made after the rain and snowfall from the days prior.   Location; 171 Metropolitan Ave, Brooklyn, NY rear of structure basement level.  a). No inspection report or competent person was on site to verify that no hazardous consition existed at the excavation site.   NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.652 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).   Location: 171 Metropolitan Ave, Brooklyn, NY rear basement level.  a). Employees were not protected from injury/death from cave in or collapse of excavation by any protection system. Employees were working within excavation of earth verticle walls to erect exterior walls of basement.   NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $0

1926.850 A

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing, floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations.   Location: 171 Metropolitan Ave, Brooklyn, NY. Interior of project.   (a) Employees had completed and were conducting interior Gut/Rehab operations of the structure. Employees did not have an engineer survey in writing that discussed the probability of an unplanned collapse.   NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • · Z (S) $2800

1926.854 D

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 27, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.854(d): Employer did not ensure that Structural or load-supporting members of the first floor system were not cut or removed until all stories above such a floor had been demolished and removed. Employees had cut the outside corner post of the temporary floor support which was more than 12 feet from teh next floor support leaving the exterior three story wall of the project unprotected from collapse.  Location: 171 Metropolitan Ave, Brooklyn, NY rear wall of project.  A) Employees had cut the temporary 2x4 stud supporting the mid span floor joist support at the basement level thereby eliminating the point load support for the three story exterior wall above.    NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1,000.00 IN ACCORDANCE WITH 29 CFR 1903.19.