Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: ASPEN AEROGELS RHODE ISLAND, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ASPEN AEROGELS RHODE ISLAND, LLC in 3 DEXTER RD, EAST PROVIDENCE, RI 02914 (NAICS 325998). OSHA activity number 339532830.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aspen Aerogels Rhode Island, LLC for free Get an email when a new federal OSHA severe-injury report for Aspen Aerogels Rhode Island, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3 DEXTER RD
City
EAST PROVIDENCE
State
RI
ZIP
02914
Mailing
3 DEXTER RD, EAST PROVIDENCE, RI 02914
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
146
Ownership type
Private (A)

4 citations on file for this inspection.

1910.119 F01 I B

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 30, 2014
Abate by
Jun 13, 2014
Penalty
Initial $6,930 · Current $5,000 Reduced
29 CFR 1910.119(f)(1)(i)(B): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information and did not address normal operations:    (a) Tank Farm: The employer did not develop and implement an adequate written procedure that provided clear instructions for safely conducting tanker truck loading operations for the ethanol loading process, such as but not limited to, procedures for selecting tankers for loading, verifying adequate tanker capacity, making line connections and equipment operation, on-going monitoring of the loading process, and emergency shut-down procedures, on or about 12-19-13.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $6930

1910.119 G01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 30, 2014
Abate by
Jun 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.119(g)(1)(i): The employer did not train each employee in the operating procedures as specified in paragraph (f) of 29 CFR 1910.119:  (a) Tank Farm: The employer did not adequately train each employee involved in tanker truck loading operations for the ethanol loading process in areas such as, but not limited to, procedures for selecting tankers for loading, verifying adequate tanker capacity, and on-going monitoring of the loading process, on or about 12-19-13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.120 Q06 II

Other-than-serious 1 instance 4 exposed
Issued
Apr 30, 2014
Abate by
Jun 13, 2014
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1910.120(q)(6)(ii): First responders at the operations level did not receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F) and/or the employer did not so certify:    (a) Tank Farm: Emergency response personnel responding to an Ethanol spill in the Tank Farm on 12-19-13 did not all receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F) and/or the employer did not so certify.
Recent events (2)
  • · I (O) $0
  • · Z (S) $3960

1910.119 D03 I C

Other-than-serious 1 instance 12 exposed
Issued
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.119(d)(3)(i)(C): Information pertaining to the equipment in the process did not include the electrical classification:  (a) Solvent Prep area: The electrical classification diagram of the Solvent Prep area did not contain any reference to reactor R-2311, on or about 12-27-13.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Aspen Aerogels Rhode Island, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339532830.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.