Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INOVA LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of INOVA LLC in 2 VANBUREN DR, ALTAMONT, NY 12009 (NAICS 337122). OSHA activity number 339534273.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inova LLC — free Get an email when a new federal OSHA severe-injury report for Inova LLC is published. One employer, no account, unsubscribe in one click.
Establishment
INOVA LLC
Site address
2 VANBUREN DR
City
ALTAMONT
State
NY
ZIP
12009
Mailing
BOX 644, ALTAMONT, NY 12009
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337122
Employees
13
Ownership type
A

16 citations on file for this inspection.

1910.107 B05 I

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarms or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained:    a)  Finishing Area - On and prior to December 30, 2013, there was no guage visible on the Global Finishing Systems Spray Booth (Model FP-1286) to determine the level of air velocity.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.107 B05 IV

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:   a)  Finishing Area - On and prior to December 30, 2013, there was no fire suppression within the on the Global Finishing Systems Spray Booth (Model FP-1286) or the exhaust ducting.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 B05 VI

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(vi): Clean filters or filter rolls were combustible or of a type having a combustibility in excess of class 2 filters as listed by Underwriters' Laboratories, Inc:   a)  Finishing Area - On and prior to December 30, 2013, a Chemco brand 6 layer paper filter was used in the Global Finishing Systems Spray Booth (Model FP-1286).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 B09

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction:   a)  Finishing Area - On and prior to December 30, 2013, the areas around the Global Finishing Systems Spray Booth (Model FP-1286) were not accessible.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 C07

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not totally enclosed to prevent the falling of hot particles:    a)  Finishing Area - On and prior to December 30, 2013, there was additional lighting within 1' of the spray booth (Husky worklight tripod stand, 2 lights) and a temporary lighting fixture was hanging over the drying area approximately 15' away of the Global Finishing Systems Spray Booth (Model FP-1286).
Recent events (3)
  • — F (S) $1000
  • — C (S) $1600
  • — Z (S) $1600

1910.305 G01 IV

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv):   a)  Manufacturing Area - On and prior to December 26, 2013, temporary lighting sets with flexible cords were used as permanent wiring.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:      a)  Finishing Area - On and prior to December 30, 2013 for the employee that is required to wear a 3M Model 6300 half face respirator while spraying stains and lacquers inside of the spray booth.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2000
  • — Z (S) $2000

1910.134 H02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:    a)  Finishing Area -  On and prior to December 30, 2013 for the employee that is required to wear a 3M Model 6300 half face respirator while spraying stains and lacquers inside of the spray booth, the respirator was not stored appropriately allowing for contamination.
Recent events (3)
  • — F (S) $1000
  • — C (S) $1200
  • — Z (S) $1200

1910.134 K03

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:   a)  Finishing Area -  On and prior to December 30, 2013 for the employee that is required to wear a 3M Model 6300 half face respirator while spraying stains and lacquers inside of the spray booth, respirator training was not provided to the Finisher.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    a)  Manufacturing Area - On and prior to December 30, 2012, employees operated a Clark powered industrial truck without conducting daily inspection.
Recent events (3)
  • — F (S) $1000
  • — C (S) $1600
  • — Z (S) $1600

1910.1200 E01

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $1,600 · Current $1,000 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program which at included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     a) Manufacturing - On and prior to December 30, 2013, for the Finisher employee(s) using chemicals such as, but not limited to, ML Campbell stains, lacquers, thinners, and sealers (containing chemicals such as Xylene, Acetone, n-Butyl Acetate, 2-Propanol, Ethanol, and Toluene -  toxic and flammable).
Recent events (3)
  • — F (S) $1000
  • — C (S) $1600
  • — Z (S) $1600

1910.1200 G08

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):  a) Manufacturing - On and prior to December 30, 2013, for the Finisher employee(s) using chemicals such as, but not limited to, ML Campbell stains, lacquers, thinners, and sealers (containing chemicals such as Xylene, Acetone, n-Butyl Acetate, 2-Propanol, Ethanol, and Toluene -  toxic and flammable).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): The employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area:  a) Manufacturing - On and prior to December 30, 2013, for the Finisher employee(s) using chemicals such as, but not limited to, ML Campbell stains, lacquers, thinners, and sealers (containing chemicals such as Xylene, Acetone, n-Butyl Acetate, 2-Propanol, Ethanol, and Toluene -  toxic and flammable).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 C01 V

Other-than-serious 1 instance 1 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $400 · Current $0 Reduced
29 CFR 1910.134(c)(1)(v): The written program did not contain procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators:      a)  Spray Booth Area -  On and prior to December 30, 2013 for the employee that is required to wear a 3M Model 6300 half face respirator while spraying stains and lacquers inside of the spray booth, the written respirator program did not contain storage or inspection requirements.
Recent events (3)
  • — F (O) $0
  • — C (O) $400
  • — Z (O) $400

1910.134 C01 VIII

Other-than-serious 1 instance 1 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $400 · Current $0 Reduced
29 CFR 1910.134(c)(1)(viii): The written program did not contain provisions for training of employees in the proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance:      a)  Spray Booth Area -  On and prior to December 30, 2013 for the employee that is required to wear a 3M Model 6300 half face respirator while spraying stains and lacquers inside of the spray booth, the written respirator program did not contain training provisions.
Recent events (3)
  • — F (O) $0
  • — C (O) $400
  • — Z (O) $400

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Mar 19, 2014
Abate by
Apr 14, 2014
Penalty
Initial $400 · Current $0 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):      a)  Manufacturing Area - On and prior to December 30, 2012, for the employees that operate a Clark powered industrial truck.
Recent events (3)
  • — F (O) $0
  • — C (O) $400
  • — Z (O) $400

View Inova LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339534273.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.