BUFFALO, NY ·
OSHA Inspection: R. E. MCNAMARA, INC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of R. E. MCNAMARA, INC. in 199 SCOTT STREET, BUFFALO, NY 14204 (NAICS 238150). OSHA activity number 339534786.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R. E. MCNAMARA, INC.
- Site address
- 199 SCOTT STREET
- City
- BUFFALO
- State
- NY
- ZIP
- 14204
- Mailing
- 5430 THOMPSON ROAD, CLARENCE, NY 14031
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 4
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.404 F06
- Issued
- Jan 29, 2014
- Penalty
- Initial $1,020 · Current $510 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 12/30/13, on third floor of construction site at the former Fairmont Creamery Building, 199 Scott St., Buffalo, NY: An employee used a Hitachi Model C8FSE Compound Miter Saw to cut aluminum strips. The saw was connected to 120-volt ac power via a series of two extension cords, the first of which was a thick yellow cord that was plugged into a wall receptacle. The second cord in the series was a short orange 3-way. The plugs on each of the two extension cords in the series lacked a grounding prong. b) On or about 12/30/13, on third floor of construction site at the former Fairmont Creamery Building, 199 Scott St., Buffalo, NY: A portable work light was connected to 120-volt ac power via a blue extension cord that was plugged into a wall receptacle. The plug on the blue extension cord lacked a grounding prong. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $510
- · Z (S) $1020
1926.416 E01
- Issued
- Jan 29, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) On or about 12/30/13, on third floor of construction site at the former Fairmont Creamery Building, 199 Scott St., Buffalo, NY: The power cord of a portable Makita Circular Saw had been frayed/cut in one spot and repaired with electrical tape. The quality of the repair was inadequate in that it was twisted & bulging, and was not near the quality of the original cord. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238150)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339534786.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.