Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: LUVATA OHIO, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of LUVATA OHIO, INC. in 1376 PITTSBURGH DR, DELAWARE, OH 43015 (NAICS 333992). OSHA activity number 339536500.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luvata Ohio, INC. for free Get an email when a new federal OSHA severe-injury report for Luvata Ohio, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
LUVATA OHIO, INC.
Site address
1376 PITTSBURGH DR
City
DELAWARE
State
OH
ZIP
43015
Mailing
1376 PITTSBURGH DR, DELAWARE, OH 43015
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
87
Ownership type
A

4 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 21, 2014
Abate by
Feb 23, 2014
Penalty
Initial $2,550 · Current $2,550
29 CFR 1910.24(h): "Railings and handrails." Standard railings shall be provided on the open sides of all exposed stairways and stair platforms.  a. In the header department, railings were not provided for the open sides of the stairway leading to the Header number 6 work platform.
Recent events (1)
  • · Z (S) $2550

1910.137 B02 VIII

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 21, 2014
Abate by
Feb 23, 2014
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-5 and Table I-6.  a. At the workplace, the employer did not ensure that electrical testing was conducted on electrical protective gloves as least every 6 months, per table I-6.
Recent events (1)
  • · Z (S) $4250

1910.212 A01

Serious Gravity 5 5 instances 14 exposed
Issued
Jan 21, 2014
Abate by
Feb 23, 2014
Penalty
Initial $4,250 · Current $4,250
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.  a. In the machining department, machine guarding was not provided for the point of operation on the #5 Davenport Machine, Serial # 12345.  b. In the machining department, machine guarding was not provided for the point of operation on the #6 Davenport Machine, Serial # 12516.   c. In the machining department, machine guarding was not provided for the point of operation on the #7 Davenport Machine, Serial # 12515.   d. In the machining department, machine guarding was not provided for the point of operation on the #8 Davenport Machine, Serial # 13626.   e. In the machining department, machine guarding was not provided for the point of operation on the #11 Davenport Machine, Serial # 13539.
Recent events (1)
  • · Z (S) $4250

1910.147 C06 II

Other-than-serious 1 instance 4 exposed
Issued
Jan 21, 2014
Abate by
Feb 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.  a. At the workplace, the employer did not certify that periodic inspections of the energy control procedures were performed.
Recent events (1)
  • · Z (O) $0

View Luvata Ohio, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339536500.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.