OSHA Inspection: CRESCENT BRASS MANUFACTURING CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CRESCENT BRASS MANUFACTURING CORPORATION in 701 PARK AVENUE, READING, PA 19611 (NAICS 331522). OSHA activity number 339538019.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crescent Brass Manufacturing Corporation — free Get an email when a new federal OSHA severe-injury report for Crescent Brass Manufacturing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
701 PARK AVENUE
City
READING
State
PA
ZIP
19611
Mailing
701 PARK AVENUE, READING, PA 19611
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331522
Employees
19
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
May 21, 2014
Abate by
Jun 17, 2014
Penalty
Initial $1,360 · Current $1,020 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by loads and/or loads falling from the hoist due to damage to the hoist pendant and missing hook latches:  (a) Rotolift Area - The hook safety latch was missing on the 1/2 ton monorail crane. The crane was used to lift the molds, on or about January 17, 2014.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1360

1910.303 B07 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 21, 2014
Abate by
Jun 17, 2014
Penalty
Initial $2,040 · Current $1,530 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in electrical boxes or housings were not effectively closed to provide  substantially equivalent protection to the wall of the equipment:  (a) Foundry pour Deck - The pendant housing on the degasser monorail crane was melted. Employees held the pendant to operate the crane and were exposed to the live 110 volt current inside the pendant, on or about January 7, 2014.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1530
  • — Z (S) $2040

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
May 21, 2014
Penalty
Initial $1,445 · Current $1,084 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) Machine Shop - The plug for the power cord for the Baldor Kalamazoo sander, serial number 34C51-5506G, did not have a ground pin, on or about January 17, 2014.      No Abatement Certification or Documentation Required.
Recent events (2)
  • — I (S) $1083.75
  • — Z (S) $1445

1910.212 B

Other-than-serious 1 instance 3 exposed
Issued
May 21, 2014
Abate by
Jun 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(b): Machines designed for a fixed location(s) were not securely anchored to prevent walking or moving:   (a) Machine Shop  - The Dayton Drill press, model number 325, serial number EH, was not anchored/bolted to the floor to prevent it from walking or moving while being used by an employee, on or about January 17, 2014.       Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Crescent Brass Manufacturing Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339538019.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.