Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G.R. HAMMONDS ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G.R. HAMMONDS ROOFING, INC. in 4211 COMMONS DR W, DESTIN, FL 32541 (NAICS 238160). OSHA activity number 339538258.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G.R. Hammonds Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for G.R. Hammonds Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4211 COMMONS DR W
City
DESTIN
State
FL
ZIP
32541
Mailing
293 ABERNATHY DR., LUMBERTON, NC 28360
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 20, 2014
Penalty
Initial $2,800 · Current $2,400 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    a.   On or about January 7, 2014, south and west sides of the building on a 5/12 pitch roof, employees were not protected from a 25 feet fall hazard by the use of a fall protection system.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 20, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a.   On or about January 7, 2014, south side of the building, the ladder used to access the roof did not extend 3 feet above the upper landing surface, exposing employees to a 25 feet fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

View G.R. Hammonds Roofing, INC.'s full OSHA safety record →