Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: REBUILD AMERICA INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REBUILD AMERICA INCORPORATED in 26 JEROME AVENUE, MINEOLA, NY 11501 (NAICS 238160). OSHA activity number 339539801.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rebuild America Incorporated — free Get an email when a new federal OSHA severe-injury report for Rebuild America Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
26 JEROME AVENUE
City
MINEOLA
State
NY
ZIP
11501
Mailing
33 LEHIGH STREET, WILLISTON PARK, NY 11596
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Jan 9, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    (a) 26 Jerome Avenue, Mineola, NY (Worksite), south and southwest sides of residential home, first story roof - An employee was re-nailing the existing roof sheathing with a pneumatic nail gunn and was not provided with; or using eye protection, which exposed the employee to serious eye injuries on, or about July 12, 2013.    (b) Worksite, north side of residential home, first story roof - Employees were re-nailing the existing roof sheathing with pneumatic nail guns and were not provided with; or using eye protection, which exposed them to serious eye injuries on, or about July 12, 2013.      Note: Abatement for this violation was previously documented; therefore, the employer is not required to submit abatement certification or documentation for this violation in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 9, 2014
Abate by
Jan 15, 2014
Penalty
Initial $2,400 · Current $1,680 Reduced
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.    (a) Worksite, west side of the residential home, ladder jack scaffold - Employees were installing 2" x 2" drip edge along the west edge of the first story roof from a ladder jack scaffold. The Werner 24' aluminum scaffold stage, Model # 2424, used to create the work platform was extended 8' beyond the south support and was not secured to prevent it from tipping, which exposed the employees to being struck-by scaffold components and a fall of 8' to the ground below on, or about July 12, 2013.    Note:The employer is required to submit abatement certification for this violation in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2400

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 9, 2014
Abate by
Jan 29, 2014
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold(s) trained by a person qualified in the subject matter to recognize those hazards associated with the type of scaffold(s) being used and to understand the procedures or controls to minimize those hazards.    (a) Worksite, west side of residential home, ladder jack scaffold - Employees were installing 2" x 2" drip edge along the west edge of the first story roof from a ladder jack scaffold. The employees were not trained to work from scaffolds; and did not recognize the hazards, which were created by the Werner 24' aluminum scaffold stage, Model # 2424, being extended 8' beyond the south ladder jack bracket on, or about July 12, 2013.     Note: The employer is required to submit abatement certification for this violation in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1926.454 B

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 9, 2014
Abate by
Jan 29, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b): The employer did not have each employee who was involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.  (a) Worksite, west side of residential home, ladder jack scaffold - Employees erected a ladder jack scaffold to perform roofing work on a residential home. The employees were not trained to erect, disassemble, move, repair, maintain, or inspect scaffolds; and did not recognize the hazards, which were created by the Werner 24' aluminum scaffold stage, Model # 2424, being extended 8' beyond the south ladder jack bracket on, or about July 12, 2013.   Note: The employer is required to submit abatement certification for this violation in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
Jan 9, 2014
Abate by
Jan 15, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a) Worksite, south side of the residential home, first story roof - Employees were engaged in re-roofing work on the first story of a residential home. The employees were working at a height of 11' on the 4:12 pitch roof and were wearing personal fall arrest harnesses, but did not have their lanyards connected to the rope stops on the vertical lifelines, which exposed the employees to a fall of 11' to the ground below on, or about July 12, 2013.    (b) Worksite, north side of the residential home, first story roof - Employees were engaged in re-roofing work on the first story of a residential home. The employees were working at a height of 11' on the 4:12 pitch roof, without fall protection, which exposed the employees to a fall of 11' to the ground below on, or about July 12, 2013.      Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339539801.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.