FAYETTEVILLE, AR ·
OSHA Inspection: NAYLOR CONCRETE & STEEL ERECTORS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NAYLOR CONCRETE & STEEL ERECTORS, LLC in 831 WEST CENTER ST., FAYETTEVILLE, AR 72701 (NAICS 238120). OSHA activity number 339542573.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAYLOR CONCRETE & STEEL ERECTORS, LLC
- Site address
- 831 WEST CENTER ST.
- City
- FAYETTEVILLE
- State
- AR
- ZIP
- 72701
- Mailing
- 198 BULL CREEK RD., MOUNT VERNON, AR 72111
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 40
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.416 A01
- Issued
- May 1, 2014
- Abate by
- May 5, 2014
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means: On or about January 3, 2014, at the worksite located at 831 West Center Street in Fayetteville, Arkansas, Level 2 of Pad G, employees were not protected against electrical shock in that they were allowed to use a bull-float equipped with an aluminum handle to perform concrete finishing tasks in proximity to energized overhead power lines. This condition exposed employees to electrocution from indirect contact with a high voltage power line.
Recent events (1)
- · Z (S) $4900
1926.416 A03
- Issued
- May 1, 2014
- Abate by
- May 5, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): Employer did not post or maintain proper warning signs at locations where the performance of the work could bring a person, tool, or machine into physical or electrical contact with an energized electrical power circuit: On or about January 3, 2014, at the worksite located at 831 West Center Street in Fayetteville, Arkansas, Level 2 of Pad G, employees used a bull-float equipped with an aluminum handle to perform concrete finishing tasks in proximity to energized overhead power lines. Warning signs were not posted to alert employees contact could be made with the energized power lines. This condition exposed employees to electrocution from indirect contact with a high voltage power line.
Recent events (1)
- · Z (S) $0
1926.702 H
- Issued
- May 1, 2014
- Abate by
- May 5, 2014
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1926.702(h): Bull floats. Bull float handles used where they might contact energized electrical conductors, shall be constructed of nonconductive material or insulated with a nonconductive sheath whose electrical and mechanical characteristics provide the equivalent protection of a handle constructed of nonconductive material: On or about January 3, 2014, at the worksite located at 831 West Center Street in Fayetteville, Arkansas, Level 2 of Pad G, employees used a bull-float equipped with an aluminum handle to perform concrete finishing tasks in proximity to energized overhead power lines. This condition exposed employees to electrocution from indirect contact with a high voltage power line.
Recent events (1)
- · Z (S) $4900
More inspections at Naylor Concrete & Steel Erectors, LLC
View Naylor Concrete & Steel Erectors, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339542573.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.