Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MALACHI 3:10 INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MALACHI 3:10 INC in 5201 LILAC AVENUE, WAUSAU, WI 54401 (NAICS 561720). OSHA activity number 339543373.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Malachi 3:10 INC — free Get an email when a new federal OSHA severe-injury report for Malachi 3:10 INC is published. One employer, no account, unsubscribe in one click.
Establishment
MALACHI 3:10 INC
Site address
5201 LILAC AVENUE
City
WAUSAU
State
WI
ZIP
54401
Mailing
5201 LILAC AVENUE, WAUSAU, WI 54401
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
11
Ownership type
A

12 citations on file for this inspection.

1910.36 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 4, 2014
Abate by
Mar 12, 2014
Penalty
Initial $1,600 · Current $1,120 Reduced
29 CFR 1910.36(c)(1): Each exit discharge did not lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside:  a)  On January 10, 2014, in the Wausau location, in the back storage area, there was a blocked exit discharge that was blocked off with insulation.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $1600

1910.37 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 4, 2014
Abate by
Mar 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp were not provided where the exit route was not substantially level:  a)   On January 10, 2014, in the Wausau location, the exit in the storage area was obstructed with 2 totes in front of the exit.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B05

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 4, 2014
Abate by
Mar 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or identified by a sign indicating its actual use (e.g. closet):  a)  On January 10, 2014, in the Wausau location, the exit doorway was closed off with insulation with the "Exit" sign on top of the doorway.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L02 II

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace:  a)   Prior to January 10, 2014, the employer did not ensure that each operator completed the forklift training, practical training, and an evaluation of the operator's performance in the workplace since 2006.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.178 L04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a)   Prior to January 10, 2014, the employer did not conduct an evaluation of the operator's performance at least once every three years.  The employer had conducted training on 10/26/2006 but no other training was conducted after that training.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The certification did not include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  a)   Prior to January 10, 2014, the employer did not conduct a certification including the name of the operator, the date of the training, the date of the evaluation, and the person performing the evaluation since 10/26/2006.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:  a)  On January 10, 2014, in the back storage room in the Wausau location, the electrical conduit and outlet box in service had been damaged.  It had been laying on the floor and had been used as an electrical power source.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.305 B02

Serious Gravity 5 3 instances 1 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a)  On January 10, 2014, three electrical outlet boxes in the back storage rooms in the Wausau site did not have electrical faceplates.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.332 B01

Serious Gravity 5 3 instances 2 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  a)  Prior to January 10, 2014, employees were not trained to acknowledge when they were exposed at the Wausau and Stratford locations to electrocution and electrical burns when handling missing ground pins on electrical cords, electrical outlets without covers, electrical boxes not properly installed on the walls, and electrical conduits not properly installed.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.334 A02 I

Serious Gravity 5 4 instances 2 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)  On January 10, 2014, the electrical cord in the Stratford location was not visually inspected before use to find out that the replaced flexible cord set contained an original female portion but the male portion was fixed incorrectly by not installing the ground pin.  b)  On January 10, 2014, the electrical outlets in the Wausau location were not visually inspected before use.  An electrical outlet was missing a faceplate.  c)  On January 10, 2014, the electrical outlets in the Wausau location were not visually inspected before use.  Two electrical outlets were not properly installed on the wall.  d) On January 10, 2014, an electrical conduit was not insulated properly, was broken, and live.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.334(a)(3)(i): A flexible cord used with the type of ground equipment did not contain an electrical equipment grounding conductor:  a)  On January 10, 2014, a flexible cord was repaired to contain an original female portion with the grounding conductor but the male portion was fixed incorrectly by not including the grounding conductor that would result in the grounding pin on the plug.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.334 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 4, 2014
Abate by
Apr 22, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles:  a) On January 10, 2014, the electrical cord in the Stratford location was altered so that the replaced flexible cord set contained an original female portion but the male portion was fixed incorrectly by not installing the ground pin.  ABATEMENT DOCUMENTATION AND ABATEMENT CERTIFICATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Malachi 3:10 INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339543373.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.