AMORY, MS ·
OSHA Inspection: TRUE TEMPER SPORTS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of TRUE TEMPER SPORTS, INC. in 101 TRUE TEMPER LANE, AMORY, MS 38821 (NAICS 331210). OSHA activity number 339543407.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRUE TEMPER SPORTS, INC.
- Site address
- 101 TRUE TEMPER LANE
- City
- AMORY
- State
- MS
- ZIP
- 38821
- Mailing
- 931 TRUE TEMPER CIRCLE, AMORY, MS 38821
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 200
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Mar 25, 2014
- Abate by
- May 9, 2014
- Penalty
- Initial $3,750 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. (a) Taper Press - On or about February 4, 2014 specific energy conrol procedures for locking out equipment prior to maintenance had not been developed.
Recent events (2)
- · I (S) $2250
- · Z (S) $3750
1910.303 G01
- Issued
- Mar 25, 2014
- Abate by
- May 9, 2014
- Penalty
- Initial $2,250 · Current $1,350 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Press Area - On or about February 4, 2014 the working space between electrical equipment and taper press was only two feet.
Recent events (2)
- · I (S) $1350
- · Z (S) $2250
1910.37 B04
- Issued
- Mar 25, 2014
- Abate by
- May 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: (a) Taper Press - On or about February 4, 2014 directional exit signs were not posted to indicate the direction of travel to the nearest exit in the event of an emergency.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 F02
- Issued
- Mar 25, 2014
- Abate by
- Apr 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Taper Press - On or about February 4, 2014 the electrical panel box was not labeled to indicate the purpose of each disconnecting means.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at True Temper Sports, INC.
View True Temper Sports, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331210)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339543407.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.