MONTOURSVILLE, PA —
OSHA Inspection: FAIRFIELD MANUFACTURING COMPANY, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FAIRFIELD MANUFACTURING COMPANY, INCORPORATED in 213 STREIBEIGH LANE, MONTOURSVILLE, PA 17754 (NAICS 332710). OSHA activity number 339543621.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAIRFIELD MANUFACTURING COMPANY, INCORPORATED
- Site address
- 213 STREIBEIGH LANE
- City
- MONTOURSVILLE
- State
- PA
- ZIP
- 17754
- Mailing
- 213 STREIBEIGH LANE, MONTOURSVILLE, PA 17754
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 21
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 B
- Issued
- Feb 4, 2014
- Abate by
- Feb 22, 2014
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. a) Back Room, 213 Streibeigh Lane, Montoursville, PA - Employees operated the Chas. G. Allen Co. drill press powered by a General Electric Model 5K225E motor (No. TJ18202) that was not securely anchored to prevent walking or moving. Employees were exposed to a struck-by hazard on or about January 16, 2014.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.147 C06 I
- Issued
- Feb 4, 2014
- Abate by
- Mar 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed. a) Maintenance, 213 Streibeigh Lane, Montoursville, PA - The employer did not conduct an inspection of the energy control procedures at least annually. Employees were exposed to machines unexpectedly energizing, starting-up, or releasing stored energy, on or about December 20, 2013. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332710)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339543621.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.