Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: CAPITAL PLUMBING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITAL PLUMBING, INC. in STONELEDGE TERRACE, BUILDINGS# 8 & 9. 18 STONELEDGE DRIVE, TROY, NY 12182 (NAICS 238220). OSHA activity number 339543894.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capital Plumbing, INC. for free Get an email when a new federal OSHA severe-injury report for Capital Plumbing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
STONELEDGE TERRACE, BUILDINGS# 8 & 9. 18 STONELEDGE DRIVE
City
TROY
State
NY
ZIP
12182
Mailing
2001 WINNERS CIRCLE, CASTLETON, NY 12033
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
10
Ownership type
Private (A)

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 21, 2014
Abate by
Feb 27, 2014
Penalty
Initial $1,200 · Current $900 Reduced
29 CFR 1926.20(b)(2):  The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  (a) Jobsite - on or about January 13, 2014 - the jobsite was not inspected by a competent person to evaluate electrical hazards in Building 8 and Building 9.
Recent events (2)
  • · I (S) $900
  • · Z (S) $1200

1926.404 B01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(i):  Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  (a) Building 9, Second Story Floor, Right Side - on or about January 13, 2014 - electric drill, Milwaukee Hole Hawg, was not protected by a Ground Fault Circuit Interrupter (GFCI).  An Assured Equipment Grounding Conductor Program was not being used.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 21, 2014
Abate by
Feb 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2):  In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  (a) Building 8, Garden Level - on or about January 13, 2014 - the 123 volt wall outlet was not provided with a cover or a faceplate.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.404 F06

Other-than-serious 1 instance 3 exposed
Issued
Feb 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  (a) Building 9, Second Story Floor, Right Side - on or about January 13, 2014 - electric drill, Milwaukee Hole Hawg, was not provided with a continual path to ground.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.416 E01

Other-than-serious 1 instance 3 exposed
Issued
Feb 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:  (a) Building 8, Garden Level - on or about January 13, 2014 - the extension cord that was used to power the electric drill had outer jacket insulation damage.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Capital Plumbing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339543894.