SELMA, AL ·
OSHA Inspection: GEORGE'S PAINT AND BODY SHOP, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of GEORGE'S PAINT AND BODY SHOP, LLC in 1215 J. L. CHESTNUT JR. BLVD, SELMA, AL 36701 (NAICS 811121). OSHA activity number 339546616.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEORGE'S PAINT AND BODY SHOP, LLC
- Site address
- 1215 J. L. CHESTNUT JR. BLVD
- City
- SELMA
- State
- AL
- ZIP
- 36701
- Mailing
- 1215 J. L. CHESTNUT JR. BLVD, SELMA, AL 36701
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 11
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.107 B10
- Issued
- Apr 28, 2014
- Penalty
- Initial $1,600 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.107(b)(10): Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination. a)Spray Paint Booth: On or about January 1st, 2014 and at times prior, the employer exposed employees chemical inhalation hazards and to fire and explosion hazards by permitting employee to performed painting and clear coating operations without effectively isolating the spraying area from the lighting unit.
Recent events (2)
- · I (S) $1000
- · Z (S) $1600
1910.134 C01
- Issued
- Apr 28, 2014
- Abate by
- May 22, 2014
- Penalty
- Initial $0 · Current $0
1539H130
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a)Paint booth and area: On or about January 14th, 2014, and prior to, the employer exposed employees to inhalation hazards from chemicals in paints to include aliphatic polyisocyanate and do not have a written respiratory protection program to include annual fit tests, medical evaluations and training on respirators and respirator care, maintenance and storage and were provided with half mask respirators.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 E01
- Issued
- Apr 28, 2014
- Penalty
- Initial $0 · Current $0
1539H130
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a)Paint booth and area: On or about January 14th, 2014, and prior to, employees were exposed to inhalation hazards from chemicals in paints to include aliphatic polyisocyanate while conducting spray painting work tasks with required use of full face and half mask respirator and not provided a medical evaluation for the respirator.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 F02
- Issued
- Apr 28, 2014
- Abate by
- May 22, 2014
- Penalty
- Initial $0 · Current $0
1539H130
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a)Paint booth and area: On or about January 14th, 2014, and prior to, employees were exposed to inhalation hazards from chemicals in paints to include aliphatic polyisocyanate while conducting spray painting work tasks with required use of a half mask respirator and not provided fit test for the respirator.