Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RICH HOME BUILDING & DEVELOPMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RICH HOME BUILDING & DEVELOPMENT in 5167 STOP 7 ROAD, WHITESBORO, NY 13492 (NAICS 238390). OSHA activity number 339546657.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rich Home Building & Development for free Get an email when a new federal OSHA severe-injury report for Rich Home Building & Development is published. One employer, no account, unsubscribe in one click.
Site address
5167 STOP 7 ROAD
City
WHITESBORO
State
NY
ZIP
13492
Mailing
1600 GIBSON ROAD, UTICA, NY 13501
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
15
Ownership type
A

9 citations on file for this inspection.

1926.153 H16

Serious Gravity 5 3 instances 15 exposed
Issued
Mar 6, 2014
Abate by
Mar 12, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1926.153(h)(16): Storage of containers awaiting use was not in accordance with paragraphs (j) and (k) of this section:    a)  At the jobsite, inside the building, in the garage, on or about 1/13/14:  A 100 lb propane gas cylinder was stored, upright, without restraint from falling, for at least one week.      b)  At the jobsite, inside the building, in the basement area, on or about 1/13/14:  A 100 lb propane gas cylinder was stored, upright, without restraiint from falling, for at least one week.    c)  At the jobsite, outside the building, next to the garage doors, on or about 1/13/14: 3 100 lb propane gas cylinders were stored, upright, without restraint from falling, for at least one week.      Abatement Certification must be submitted for this item.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1926.153 O

Serious Gravity 1 1 instance 15 exposed
Issued
Mar 6, 2014
Abate by
Mar 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken:  a)  At the jobsite, outside the building, next to the garage doors, on or about 1/13/14: 3 100 lb propane gas cylinders were stored, upright, without restraint from falling, without protection from vehicle traffic, for at least one week.    Abatement Certification must be submitted for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.304 H01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut.  a)  At the jobsite, inside the garage, on or about 1/13/14:  A DeWALT table saw was being used to cut material without a guard in place.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1600

1926.403 B02

Deleted Serious Gravity 5 3 instances 4 exposed
Issued
Mar 6, 2014
Abate by
Mar 12, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.  a)  At the jobsite, in the garage, on or about 1/13/14:  Employees were using a table saw and a chop saw powered through a quad outlet not designed for this purpose.    b)  At the jobsite, on the main floor, on or about 1/13/14:  Employees were providing power to lighting through a quad outlet not designed for this purpose.  c)  At the jobsite, in the basement, on or about 1/13/14:  An electrical service panel was covered with cardboard.  Abatement certification must be submitted for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $1600

1926.404 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:   a)  On the jobsite, inside the garage, on or about 1/13/14:  Employees were using a DeWALT table saw and a DeWALT radial saw, both powered from an outlet that was not GFI protected.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.405 G02 IV

Serious Gravity 1 4 instances 15 exposed
Issued
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): The employer shall ensure that flexible cords are connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.  a)  At the jobsite, in the garage, on or about 1/13/14:  Employees were using power tools connected to a quad outlet where the cord was pulled free from the housing.  b)  At the jobsite, in the garage, on or about 1/13/14:  Employees were using a DeWALT radial saw where the power connection was pulled free from the saw.  c)  At the jobsite, in the basement, on or about 1/13/14:  Employees were working in close proximity to power cords that were pulled free from the plugs.  Those cords were used to provide lighting.    d)  At the jobsite, on the main floor, on or about 1/13/14:  Employees were working in close proximity to power cords that were pulled free from the plugs.  Those cords were used to provide lighting and power hand tools.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 F07

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 6, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:  a)  At the jobsite, in the garage, on or about 1/13/14:  Employees assembled a supported scaffold where the upper working platform, approximately 12 feet from ground, was not fully planked, and did not provide fall protection.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.451 B01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:  a)  At the jobsite, in the garage, on or about 1/13/14:  Employees worked from a supported scaffold where the upper working platform, approximately 12 feet from ground, was not fully planked, and did not provide fall protection.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.451 G01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1m) above a lower level was not protected from falling to that lower level in accordance with paragraphs (g)(1)(i) through (vii) of this section:  a)  At the jobsite, in the garage, on or about 1/13/14:  Employees worked from a supported scaffold where the upper working platform, approximately 12 feet from ground, was not fully planked, and without fall protection.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339546657.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.