Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: U.S. DEPARTMENT OF THE AIRFORCE, INDIANA AIR NATIONAL GUARD, 122 FIGHTER WING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF THE AIRFORCE, INDIANA AIR NATIONAL GUARD, 122 FIGHTER WING in 3005 FERGUSON ROAD, FORT WAYNE, IN 46809 (NAICS 928110). OSHA activity number 339546798.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of the Airforce, Indiana AIR National Guard, 122 Fighter Wing for free Get an email when a new federal OSHA severe-injury report for U.S. Department of the Airforce, Indiana AIR National Guard, 122 Fighter Wing is published. One employer, no account, unsubscribe in one click.
Site address
3005 FERGUSON ROAD
City
FORT WAYNE
State
IN
ZIP
46809
Mailing
3005 FERGUSON ROAD, FORT WAYNE, IN 46809
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
960
Ownership type
Federal government (D)

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 60 exposed
Issued
Feb 6, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    (a) On or about January 14, 2014, in the Vehicle Maintenance Shop in Building 798, no method of machine guardinging was installed on the Northern Industrial Floor Drill-press potentially exposing employees whom utilized the drill press to ingoing nip point and rotating parts hazards.        (b) On or about January 22, 2014, in the Metal Technology Shop in Building 758, no method of machine guardinging was installed on the Rockwell Drill Press, Serial Number CR 4SC17D192FECCW, potentially exposing employees whom utilized the drill press to ingoing nip point and rotating parts hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 D03

Serious Gravity 5 1 instance 15 exposed
Issued
Feb 6, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(d)(3): The surface of the abarasive wheel was observed with foreign materials build-up. All contact surfaces of wheels, blotters and flanges shall be flat and free of foreign matter.    On or about January 23, 2014, at the Jet Propulsion/ Engine shop, in Buidling 756, there was a build-up,of foreign on the surface the grinding wheel.  This potentially exposed employees to struck-by hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1001 J07 IV

Serious Gravity 5 7 instances 100 exposed
Issued
Feb 6, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1001(j)(7)(iv): The employer did not provide training to employees who perform housekeeping operations in an area which contains ACM or PACM, an asbestos awareness training course.  On or about January 14, 2014, the Indiana Air National Guard did not provide asbestos awareness training to employees whom perform housekeeping or response to fiber release episode clean-up. Employees were potentially exposed to cancer and lung disease hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.179 K02

Other-than-serious 2 instances 30 exposed
Issued
Feb 6, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.179(k)(2): Rated load test. Test loads shall not be more than 125 percent of the rated load unless otherwise recommended by the manufacturer. The test reports shall be placed on file where readily available to appointed personnel.    (a) On or about January 22, 2014, at the Aerospace Ground Equpment Shop, in Building 768, no rated load test report was provided for Crane GOHH.    (b) On or about January 23 at the Jet Propulsion/Engine Shop, Building 756, no rated load test report was provided for the overhead electric hoist, GZ-118.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339546798.