WOBURN, MA ·
OSHA Inspection: ATLANTIC PLYWOOD CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ATLANTIC PLYWOOD CORPORATION in 8 ROESSLER ROAD, WOBURN, MA 01801 (NAICS 423310). OSHA activity number 339546855.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATLANTIC PLYWOOD CORPORATION
- Site address
- 8 ROESSLER ROAD
- City
- WOBURN
- State
- MA
- ZIP
- 01801
- Mailing
- 8 ROESSLER ROAD, WOBURN, MA 01801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 52
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.37 A03
- Issued
- Feb 7, 2014
- Penalty
- Initial $3,577 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp were not provided where the exit route was not substantially level: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, an inside flammable storage room exit was blocked from the inside by a stack of empty pallets and empty cardboard boxes.
Recent events (2)
- · I (S) $2150
- · Z (S) $3577
1910.106 E02 II B 2
- Issued
- Feb 7, 2014
- Penalty
- Initial $4,208 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b)(2): The quantity of Category 2, 3, or 4 flammable liquid located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building exceeded 120 gallons: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, fifty-five gallon metal drums containing xylene, a Category 3 flammable liquid, and five gallon metal containers container lacquer thinner, a Category 2 flammable liquid, were allowed to accumulate in excess of 120 gallons in one area outside of the employer's inside storage room.
Recent events (2)
- · I (S) $2100
- · Z (S) $4208
1910.178 L01 II
- Issued
- Feb 7, 2014
- Abate by
- Mar 14, 2014
- Penalty
- Initial $4,208 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, an employee who had not received forklift training from the employer was permitted to operate a forklift for purposes other than training.
Recent events (2)
- · I (S) $2100
- · Z (S) $4208
1910.178 M02
- Issued
- Feb 7, 2014
- Abate by
- Mar 14, 2014
- Penalty
- Initial $3,366 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.178(m)(2): Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s): (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, employees reached under the live load of a forklift to band plywood.
Recent events (2)
- · I (S) $2000
- · Z (S) $3366
1910.178 M05 I
- Issued
- Feb 7, 2014
- Abate by
- Mar 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not neutralized, power was not shut off, and brakes set: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, forklift operators in the warehouse left their lifts unattended without fully lowering load engaging means and shutting off the power.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 H01
- Issued
- Feb 7, 2014
- Abate by
- Mar 14, 2014
- Penalty
- Initial $4,208 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, employees who operate forklifts in proximity to fifty-five gallon drums of xylene and five gallon containers of lacquer thinner within the facility were not provided hazard communication training. (b) Location - 8 Roessler Road, Woburn, MA; On or about 1/14/2014, employees assigned to mix lacquers were not provided hazard communication training.
Recent events (2)
- · I (S) $2100
- · Z (S) $4208
1910.1200 E01
- Issued
- Feb 7, 2014
- Abate by
- Mar 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, the employer has not developed and implemented a written hazard communication program detailing how the requirements of 29 CFR 1910.1200(f), (g), and (h) will be met.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.157 C01
- Issued
- Feb 7, 2014
- Penalty
- Initial $2,146 · Current $500 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) Location - 8 Roessler Road, Woburn, MA: On or about 1/14/2014, access to a mounted portable fire extinguisher was blocked by plywood in storage.
Recent events (2)
- · I (O) $500
- · Z (S) $2146
More inspections at Atlantic Plywood Corporation
View Atlantic Plywood Corporation's full OSHA safety record →
More inspections in this industry (NAICS 423310)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339546855.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.