FURLONG, PA —
OSHA Inspection: REOBOTE CONSTRUCTION INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of REOBOTE CONSTRUCTION INC. in 2523 HERITAGE CENTER DR., FURLONG, PA 18925 (NAICS 238130). OSHA activity number 339548174.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REOBOTE CONSTRUCTION INC.
- Site address
- 2523 HERITAGE CENTER DR.
- City
- FURLONG
- State
- PA
- ZIP
- 18925
- Mailing
- 1706 ARNOLD STREET, PHILADELPHIA, PA 19152
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 28, 2014
- Abate by
- Apr 12, 2014
- Penalty
- Initial $2,040 · Current $1,530 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing for likely to cause death or serious physical harm to employees in that employees were exposed to caught between/struck-by hazards and resulting blunt force trauma from roof truss collapse: a) Construction site, 2523 Heritage Center Drive, Building 500 - On or about January 9, 2014 Employees were installing lateral bracing on trusses spanning 43 feet, and did not install adequate temporary Top Chord Temporary Lateral Restraint (TCTLR) or bracing, resulting in a collapse of all the trusses erected between the girder trusses. Among other methods, one feasible and acceptable abatement method would be: Follow recommendations of the Truss Plate Institute and Wood Truss Council of America BCSI-B2 or the BCSI-B2 Summary sheet Guide for Installation and Temporary Bracing, that was provided with the trusses by the manufacturer. These recommendations would include but not be limited to the following: 1. Install TCTLR as specified in steps 1 through 5 with maximum 8 feet on center as specified in table B2-1. 2. Install sheathing immediately as stated in the Step 5 regarding installing top chord diagonal bracing. 3. Install temporary bracing throughout, as specified in step 5 thru 8. 4. Pre-assemble trusses for installation as shown in alternate methods on p5, or as documented in BCSI-B11.
Recent events (2)
- — I (S) $1530
- — Z (S) $2040
1926.416 E01
- Issued
- Mar 28, 2014
- Penalty
- Initial $867 · Current $650 Reduced
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Construction site, Heritage Center building 500 - On or about January 9, 2014, employees utilized an extension cord with significant damage to the protective sheathing and plug area, to power hand tools with a generator, exposing them to an electric shock hazard.
Recent events (2)
- — I (S) $650.25
- — Z (S) $867
More inspections at Reobote Construction INC.
View Reobote Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339548174.