PALM CITY, FL ·
OSHA Inspection: SOL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOL INC. in 3210 SW 42ND AVE, PALM CITY, FL 34990 (NAICS 335129). OSHA activity number 339548455.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOL INC.
- Site address
- 3210 SW 42ND AVE
- City
- PALM CITY
- State
- FL
- ZIP
- 34990
- Mailing
- 3210 SW 42ND AVE, PALM CITY, FL 34990
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335129
- Employees
- 29
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Feb 7, 2014
- Abate by
- Feb 20, 2014
- Penalty
- Initial $2,975 · Current $1,785 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about November 1, 2013, at the warehouse area, an employee was exposed to a caught by hazard while cutting wood with a chopsaw (i.e. Dewalt, Model Number D2825, Serial Number 095170) that lacked a guard.
Recent events (2)
- · I (S) $1785
- · Z (S) $2975
1910.242 B
- Issued
- Feb 7, 2014
- Abate by
- Feb 20, 2014
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a. On or about January 14, 2014, at the assembly area of the above addressed worksite, an employee was exposed to a struck by hazard while using compressed air for cleaning purposes at 50 psi.
Recent events (2)
- · I (S) $1071
- · Z (S) $1785
1910.303 B02
- Issued
- Feb 7, 2014
- Abate by
- Feb 14, 2014
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a. On or about January 14, 2014, at the assembly area of the above addressed worksite, employees were exposed to an electrical hazard while plugging/energizing electrical equipment from a receptacle installed within a junction box which was not secured.
Recent events (2)
- · I (S) $1428
- · Z (S) $2380
1910.304 G05
- Issued
- Feb 7, 2014
- Abate by
- Feb 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a. On or about January 14, 2014, at the assembly area of the above addressed worksite, a fan (i.e. Model # FE-50) was not provided with a continuous path to ground, exposing employees to an electrical hazard. b. On or about January 14, 2014, at the assembly area of the above addressed worksite, an employee was exposed to an electrical hazard while soldering cables with an iron that lacked a continuous path to ground.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.178 P01
- Issued
- Feb 7, 2014
- Abate by
- Feb 14, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a. On or about January 14, 2014, at the warehouse area of the above addressed worksite, employees were exposed to a struck by hazard while driving a powered industrial truck (i.e. Yale, Serial No. E187VI56084) that had one of its back indicator lights broken.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 335129)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339548455.