OSHA Inspection: SOL INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOL INC. in 3210 SW 42ND AVE, PALM CITY, FL 34990 (NAICS 335129). OSHA activity number 339548455.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch SOL INC. for free Get an email when a new federal OSHA severe-injury report for SOL INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SOL INC.
Site address
3210 SW 42ND AVE
City
PALM CITY
State
FL
ZIP
34990
Mailing
3210 SW 42ND AVE, PALM CITY, FL 34990
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335129
Employees
29
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2014
Abate by
Feb 20, 2014
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   a.   On or about November 1, 2013, at the warehouse area, an employee was exposed to a caught by hazard while cutting wood with a chopsaw  (i.e. Dewalt, Model Number D2825, Serial Number 095170) that lacked a guard.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 7, 2014
Abate by
Feb 20, 2014
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:   a.  On or about January 14, 2014, at the assembly area of the above addressed worksite, an employee was exposed to a struck by hazard while using compressed air for cleaning purposes at 50 psi.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.303 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2014
Abate by
Feb 14, 2014
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a.  On or about January 14, 2014, at the assembly area of the above addressed worksite, employees were exposed to an electrical hazard while plugging/energizing electrical equipment from a receptacle installed within a junction box which was not secured.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.304 G05

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 7, 2014
Abate by
Feb 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a.  On or about January 14, 2014, at the assembly area of the above addressed worksite, a fan (i.e. Model # FE-50) was not provided with a continuous path to ground, exposing employees to an electrical hazard.   b.  On or about January 14, 2014, at the assembly area of the above addressed worksite, an employee was exposed to an electrical hazard while soldering cables with an iron that lacked a continuous path to ground.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 P01

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2014
Abate by
Feb 14, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(p)(1):  Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):  a.  On or about January 14, 2014, at the warehouse area of the above addressed worksite, employees were exposed to a struck by hazard while driving a powered industrial truck (i.e. Yale, Serial No. E187VI56084) that had one of its back indicator lights broken.