SALAMANCA, NY —
OSHA Inspection: MCHONE INDUSTRIES INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MCHONE INDUSTRIES INC in 110 ELM STREET, SALAMANCA, NY 14779 (NAICS 333999). OSHA activity number 339548539.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MCHONE INDUSTRIES INC
- Site address
- 110 ELM STREET
- City
- SALAMANCA
- State
- NY
- ZIP
- 14779
- Mailing
- 110 ELM STREET, SALAMANCA, NY 14779
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 84
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.36 A02
- Issued
- Jul 9, 2014
- Abate by
- Aug 21, 2014
- Penalty
- Initial $1,785 · Current $1,339 Reduced
General-duty citation text
29 CFR 1910.36(a)(2): An exit must be separated by fire resistant materials. Construction materials used to separate an exit from other parts of the workplace must have a one-hour fire resistance-rating if the exit connects three or fewer stories and a two-hour fire resistance-rating if the exit connects four or more stories. a) On or about 4/24/14, front stairwell exit did not meet the one-hour fire resistance rating due to numerous penetrations in the walls and ceiling. Abatement Certification Required:
Recent events (2)
- — I (S) $1338.75
- — Z (S) $1785
1910.22 D01
- Issued
- Jul 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official shall be marked on plates of approved design which shall be supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate. Such plates shall not be removed or defaced but, if lost, removed, or defaced, shall be replaced by the owner or his agent. a) On or about 4/24/14, mezzanine that was use as storage for boxes business records, did not have a load capacity plate. No Abatement Required:
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B06
- Issued
- Jul 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 foot lamberts (0.21 cd/m2) are permitted. a) On or about 4/24/14 in the shipping area, exit sign above the exit door was not illuminated making it difficult to see in the darken hallway. No Abatement Required:
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mchone Industries INC
View Mchone Industries INC's full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339548539.