AMHERST, NY —
OSHA Inspection: RICMAR ELECTRIC, INC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of RICMAR ELECTRIC, INC in 2277 NIAGARA FALLS BLVD, AMHERST, NY 14228 (NAICS 238210). OSHA activity number 339551293.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RICMAR ELECTRIC, INC
- Site address
- 2277 NIAGARA FALLS BLVD
- City
- AMHERST
- State
- NY
- ZIP
- 14228
- Mailing
- 7293 SCHULTZ ROAD, NORTH TONAWANDA, NY 14120
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.405 E01
- Issued
- Jan 30, 2014
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: a) On or about 1/15/14, at the site of Amherst, NY. Outdoor receptacle boxes, that were in use, lacked the covers. No Abatement Certification Required
Recent events (3)
- — J (O) $0
- — C (S) $1200
- — Z (S) $1200
1926.405 J01 II
- Issued
- Jan 30, 2014
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported: a) On or about 1/15/14, at the shop area of the site, Amherst, NY. A receptacle box, that was in use, was not securely supported. No Abatement Certification Required
Recent events (3)
- — J (O) $0
- — C (S) $1200
- — Z (S) $1200
1926.405 A02 II C
- Issued
- Jan 30, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(C): Receptacles for uses other than temporary lighting were installed on branch circuits which supplied temporary lighting: a) On or about 1/15/14, at the office area of the site, Amherst, NY. Temporary lighting was plugged into a 3-way receptacle that supplied power to the tools. No dedicated circuit was provided. No Abatement Certification Required
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Ricmar Electric, INC
View Ricmar Electric, INC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339551293.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.