Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: QUALITY METALS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of QUALITY METALS in 210 W. PEDEN, SAN ANTONIO, TX 78204 (NAICS 332312). OSHA activity number 339551376.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Metals — free Get an email when a new federal OSHA severe-injury report for Quality Metals is published. One employer, no account, unsubscribe in one click.
Establishment
QUALITY METALS
Site address
210 W. PEDEN
City
SAN ANTONIO
State
TX
ZIP
78204
Mailing
210 W. PEDEN, SAN ANTONIO, TX 78204
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
50
Ownership type
A

11 citations on file for this inspection.

1910.141 A03 I

Serious Gravity 1 1 instance 6 exposed
Issued
May 30, 2014
Abate by
Jun 5, 2014
Penalty
Initial $2,100 · Current $1,260 Reduced
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:      Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to the health hazard of wood dust, an eye and respirator irritant while working on and near the box making area of the main warehouse.
Recent events (2)
  • — I (S) $1260
  • — Z (S) $2100

1910.147 C01

Serious Gravity 5 1 instance 3 exposed
Issued
May 30, 2014
Abate by
Jul 31, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:        In main warehouse: On or about January, 13, 2014 and at times prior thereto, employees were exposed to a caught-in hazard while adjusting slitter machine without an established written Lock Out Tag Out Program.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.147 D03

Serious Gravity 5 1 instance 3 exposed
Issued
May 30, 2014
Abate by
Jun 9, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:      In main warehouse: On or about January, 13, 2014 and at times prior thereto, employees were exposed to a caught-in hazard while adjusting slitter machine without lock out tag out equipment.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.178 A04

Serious Gravity 5 1 instance 6 exposed
Issued
May 30, 2014
Abate by
Jun 9, 2014
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:      In main warehouse and yard: On or about January, 13, 2014 and at times prior thereto, employees were exposed to a struck-by hazard while using Toyota Forklift Model 8FGCU25, Serial 45311 with a modified forklift tine (hole in fork) that significantly reduces the lifting capacity of the tine resulting in possible cataclysmic failure.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.242 B

Serious Gravity 10 1 instance 3 exposed
Issued
May 30, 2014
Abate by
Jun 9, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to the struck-by and health hazard of using compressed air over 30 p.s.i. to clean machine equipment.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.254 D07

Serious Gravity 5 1 instance 7 exposed
Issued
May 30, 2014
Abate by
Jun 5, 2014
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.254(d)(7): Electrode holders when not in use were not so placed that they could not make electrical contact with persons, conducting objects, fuel or compressed gas tanks:      Main warehouse: On or about January 13, 2014, and at times prior thereto, employees were exposed to an electrical hazard while using a Lincoln Electric AC-225 arc welder with damage to the rod holder cord.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.254 D08

Serious Gravity 5 1 instance 1 exposed
Issued
May 30, 2014
Abate by
Jun 9, 2014
Penalty
Initial $3,500 · Current $2,100 Reduced
29 CFR 1910.254(d)(8): Welding cables with splices within 10 feet (3 m) of the holder were used:      Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while using a Lincoln Electric AC-225 arc welder with damage to the rod holder cord.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.305 B01

Serious Gravity 10 2 instances 6 exposed
Issued
May 30, 2014
Abate by
Jul 31, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:        a) Main warehouse near rollup door: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while turning on warehouse lights in the dark near open breaker panels that were missing breakers or covers.        b) Main warehouse, center: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while operating Jinggong Science & Technology R-Panel machine with missing knock-outs on breaker panel.
Recent events (2)
  • — I (S) $2940
  • — Z (S) $4900

1910.305 B02 I

Serious Gravity 5 4 instances 8 exposed
Issued
May 30, 2014
Abate by
Jun 6, 2014
Penalty
Initial $4,200 · Current $2,520 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:        a) Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while turning on warehouse lights using switches without faceplates.       b) Renovated office: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while turning on office lights to access the warehouse using switches without faceplates.      c) Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while using the Jingong R-Panel machine with missing cover over its junction box.      d) Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while using the Industrial Air Compressor Model:ILA1883054 with missing cover over its junction box.
Recent events (2)
  • — I (S) $2520
  • — Z (S) $4200

1910.305 G02 II

Serious Gravity 5 1 instance 6 exposed
Issued
May 30, 2014
Abate by
Jun 5, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:       Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while using Lincoln Electric ARC-225 welder machine plugged into an extension cord made up of two cords spliced together.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 G02 III

Serious Gravity 5 1 instance 4 exposed
Issued
May 30, 2014
Abate by
Jun 9, 2014
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:       Main warehouse: On or about January 13, 2014, and at times prior thereto employees were exposed to an electrical hazard while using Jinggong S&T R-Panel machine with obvious strain-relief damage to its cord in the operators area.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800