Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: ATLANTIC PLUMBING SUPPLY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATLANTIC PLUMBING SUPPLY in 75 LONG BRANCH AVENUE, LONG BRANCH, NJ 07740 (NAICS 423720). OSHA activity number 339551996.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Plumbing Supply — free Get an email when a new federal OSHA severe-injury report for Atlantic Plumbing Supply is published. One employer, no account, unsubscribe in one click.
Site address
75 LONG BRANCH AVENUE
City
LONG BRANCH
State
NJ
ZIP
07740
Mailing
702 JOLINE AVENUE, LONG BRANCH, NJ 07740
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423720
Employees
60
Ownership type
A

5 citations on file for this inspection.

1910.24 H

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 20, 2014
Abate by
Apr 30, 2014
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms:    a) Furnace area: A standard railing was not installed on each side of the stairs leading to the tractor trailer used by the company as storage for products in stock, on or about 7/23/13.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.1200 E01

Other-than-serious 1 instance 2 exposed
Issued
Mar 20, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1):     The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) Throughout facility: The employer did not develop and implement a written hazard communication program for the chemicals used throughout the facility by the employees, such as diesel and cleaning chemicals, on or about 1/16/2014.     NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 2 exposed
Issued
Mar 20, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1):      Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:    a) Throughout facility: The employer has all the safety data sheets at the main warehouse, however the SDSs for the chemicals used at the satellite sites are not available at those locations, on or about 01/16/2014.     NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Mar 20, 2014
Abate by
Apr 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1):     Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) Throughout facility: The employer did not provide HAZCOM training for the chemicals used throughout the facility by the employees, such as, but not limited to Diesel and cleaners, on or about 1/16/2014.     NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.141 D02 II

Other-than-serious 1 instance 2 exposed
Issued
Mar 20, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water:   a) Toilet facilities:  The employer did not provide running water for employees after using the toilet, on or about 01/16/2014.