EL PASO, TX ·
OSHA Inspection: TIERRA FIRME INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of TIERRA FIRME INC. in 400 REVERE ST., EL PASO, TX 79905 (NAICS 238110). OSHA activity number 339552150.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TIERRA FIRME INC.
- Site address
- 400 REVERE ST.
- City
- EL PASO
- State
- TX
- ZIP
- 79905
- Mailing
- 5861 CLEVELAND AVE., EL PASO, TX 79905
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 B01
- Issued
- Feb 19, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $1,200 · Current $700 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On or about January 16, 2014, at Fire Station #5 under construction, the DeWalt 4 ½ inches Angle Grinder (Model #D28402 Serial #584992) used by employees to grind down reinforced steel did not have a guard. Employees were exposed to struck-by hazards.
Recent events (2)
- · I (S) $700
- · Z (S) $1200
1926.403 B01
- Issued
- Feb 19, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: On or about January 16, 2014, at Fire Station #5 under construction, the employer did not ensure that electrical equipment was free from recognized hazards that were likely to cause death or serious physical harm to employees: 1) The insulation of a 50-foot yellow extension cord used to power the DeWalt 4 ½ inches Angle Grinder (Model #D28402 - Serial #584992) was cut through, exposing bare conductors. 2) The insulation of a 25-foot red/black extension cord used to power the Craftsman Industrial 7 ¼ inches Worm Drive Saw (Serial #C381972) had strain relief broken, exposing bare conductors. 3) The cord insulation of a 25-foot red/black extension cord used to power the Craftsman Industrial 7 ¼ inches Worm Drive Saw (Serial #C381972) had strain relief broken, exposing bare conductors. 4) The 100-foot red/black extension cord (one of four extension cords connected together) used to power the Craftsman Industrial 7 ¼ inches Worm Drive Saw (Serial #C381972) had outer insulation damaged throughout the length of the cord.
Recent events (2)
- · I (S) $2000
- · Z (S) $2800
1926.405 A02 II I
- Issued
- Feb 19, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage: On or about January 16, 2014, at Fire Station #5 under construction, extension cords strung across the roadway were not protected from damage caused by a traversing front-loader; employees were exposed to electrical shock hazards. 1) The insulation of a 50-foot yellow extension cord used to power the DeWalt 4 ½ inches Angle Grinder (Model #D28402 - Serial #584992) was cut through, exposing bare conductors. 2) The 100-foot red/black extension cord (one of four extension cords connected together) used to power the Craftsman Industrial 7 ¼ inches Worm Drive Saw (Serial #C381972) had outer insulation damaged throughout the length of the cord.
Recent events (2)
- · I (S) $0
- · Z (S) $2800
1926.701 B
- Issued
- Feb 19, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $2,400 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about January 16, 2014, at Fire Station #5 under construction, concrete reinforcing steel bars sticking vertically out of the ground and horizontally out of concrete wall were left unprotected. Employees were exposed to impalement hazards.
Recent events (2)
- · I (S) $2000
- · Z (S) $2400
1926.405 G01 I
- Issued
- Feb 19, 2014
- Abate by
- Mar 17, 2014
- Penalty
- Initial $400 · Current $100 Reduced
General-duty citation text
29 CFR 1926.405(g)(1)(i): Flexible cords and cables were not suitable for conditions of use and location: On or about January 16, 2014, at Fire Station #5 under construction, employees had four electrical extension cords plugged together in order to supply power to their electrical equipment. The employer did not ensure that employees followed manufacturers instructions. The employees were exposed to electrical shock.
Recent events (2)
- · I (O) $100
- · Z (O) $400
More inspections at Tierra Firme INC.
View Tierra Firme INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339552150.