EL PASO, TX —
OSHA Inspection: NEW LIFE CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NEW LIFE CONSTRUCTION in 11995 MONTWOOD DR., EL PASO, TX 79936 (NAICS 238310). OSHA activity number 339552234.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEW LIFE CONSTRUCTION
- Site address
- 11995 MONTWOOD DR.
- City
- EL PASO
- State
- TX
- ZIP
- 79936
- Mailing
- P.O. BOX 26008, EL PASO, TX 79926
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 B01
- Issued
- Mar 24, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): 29 CFR 1926.450(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports: On or about January 16, 2014, at the Cross Point Church under construction, two employees were observed working on a two-tier scaffold that was not fully planked. On the second-tier, one employee was exposed to a fall greater than 10-feet.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.451 C02
- Issued
- Mar 24, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates: On or about January 16, 2014, at the Cross Point Church under construction, two employees were observed working on a two-tier scaffold that did not bear base plates. From the second-tier, one employee was exposed to a fall greater than 10-feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Mar 24, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: On or about January 16, 2014, at the Cross Point Church under construction, two employees working on a scaffold were observed climbing up and down from the scaffold without the use of a proper ladder. A six-foot A-Frame Werner ladder was used to climb up to the first tier of the scaffold, from there the employees used the sections of the frame to egress and access the second tier of the scaffold. The employees were exposed to slip and fall hazards from the lack of scaffold access.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.1053 B04
- Issued
- Mar 24, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were not used for the purpose for which they were designed: On or about January 16, 2014, at the Cross Point Church under construction, two employees working on a scaffold were observed climbing up and down from the scaffold and the roof without the use of a proper ladder. The employees were exposed to slip and fall hazards greater than 10-feet. 1) A 6-foot A-Frame Werner ladder was used to climb up to the first tier of the scaffold; from there the employees used the sections of the frame to egress and access the second tier of the scaffold. 2) A 12-foot A-frame Werner ladder leaned against the side of the building was used to access the approximately 12-feet above the ground.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Mar 24, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: On or about January 16, 2014, at the Cross Point Church under construction, one employee was observed working on the second-tier of a scaffold without any form of fall protection. Employees were exposed to a fall greater than 10-feet.
Recent events (2)
- — I (S) $800
- — Z (S) $1600
1926.454 C03
- Issued
- Mar 24, 2014
- Abate by
- Mar 28, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(c)(3): The employer had not retrained employees that showed indications through work performance of not retaining the requisite proficiency: On or about January 16, 2014, at the Cross Point Church under construction, one employee was observed working on the second-tier of a scaffold without any form of fall protection. Inadequacies in an affected employees work involving scaffolds indicate that the employees had not retained the requisite proficiency. Employees were exposed to a fall greater than 10-feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at NEW Life Construction
View NEW Life Construction's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339552234.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.