Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAF USA INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CAF USA INC. in 300 EAST EIGHTEENTH STREET, ELMIRA HEIGHTS, NY 14903 (NAICS 336510). OSHA activity number 339554396.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CAF USA INC. — free Get an email when a new federal OSHA severe-injury report for CAF USA INC. is published. One employer, no account, unsubscribe in one click.
Establishment
CAF USA INC.
Site address
300 EAST EIGHTEENTH STREET
City
ELMIRA HEIGHTS
State
NY
ZIP
14903
Mailing
300 EAST EIGHTEENTH STREET, ELMIRA HEIGHTS, NY 14903
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336510
Employees
550
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 3 instances 15 exposed
Issued
Feb 18, 2014
Abate by
Feb 28, 2014
Penalty
Initial $3,000 · Current $1,950 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:   a) On or about 1/17/14, Test Bay:  End of Amtrak vehicle.  No midrail was provided at the car end opening.  Employees exposed to falls of eight feet, six inches.      b) On or about 1/17/14, Test Bay:  Side of Amtrak vehicle.  No midrail was provided at the car side opening.  Employees exposed to falls of four feet, ten inches.     c) On or about 1/17/14, final Assemble, Building #4:  No guardrail system was provided at the end of a rail car, at the access point. Employees exposed to falls of over four feet due to the access stairs configuaration.   Abatement certification is required for these items.
Recent events (2)
  • — I (S) $1950
  • — Z (S) $3000

1910.303 G02 I

Serious Gravity 5 2 instances 10 exposed
Issued
Feb 18, 2014
Abate by
Feb 28, 2014
Penalty
Initial $5,000 · Current $3,250 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) On or about 1/17/14, Test Bay:  Inside a Houston car, a heater had exposed, energized 480 volt terminals.  b) On or about 1/17/14, Test Bay:  Inside a Houston car, empty light sockets had exposed, energized 120 volt parts.    Abatement certification is required for these items.
Recent events (2)
  • — I (S) $3250
  • — Z (S) $5000

1910.333 B02

Serious Gravity 10 2 instances 10 exposed
Issued
Feb 18, 2014
Abate by
Feb 28, 2014
Penalty
Initial $7,000 · Current $4,550 Reduced
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2):   a) On or before 1/17/14, Test Bay:  Employees were working on and near 480 Volt AC circuits that were not locked out.  A circuit was re energized while employees were exposed.   b) On or about 1/17/14, Test Bay:  Employees were working on and near 650 Volt DC circuits without each employee applying a lock out device.   Abatement documentation is required for this item.
Recent events (2)
  • — I (S) $4550
  • — Z (S) $7000

1910.147 C06 I

Other-than-serious 1 instance 15 exposed
Issued
Feb 18, 2014
Abate by
Feb 28, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a) On or about 1/17/14, Throughout the facility:  No periodic review and/ or inspection of the companies energy control procedures was conducted.         Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CAF USA INC.'s full OSHA safety record →