SOUTH PORTLAND, ME —
OSHA Inspection: HANNAFORD BROTHERS DISTRIBUTION CENTER 01
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HANNAFORD BROTHERS DISTRIBUTION CENTER 01 in DARTMOUTH STREET, SOUTH PORTLAND, ME 04106 (NAICS 493120). OSHA activity number 339554925.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HANNAFORD BROTHERS DISTRIBUTION CENTER 01
- Site address
- DARTMOUTH STREET
- City
- SOUTH PORTLAND
- State
- ME
- ZIP
- 04106
- Mailing
- 50 HEMCO ROAD, SOUTH PORTLAND, ME 04106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493120
- Employees
- 450
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.119 F01
- Issued
- Mar 4, 2014
- Abate by
- Mar 21, 2014
- Penalty
- Initial $5,500 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process: 1987 Freezer/Dairy Anhydrous Ammonia Refrigeration System - The employer did not develop and implement a written ammonia charging procedure that was consistent with the ammonia charging practice.
Recent events (2)
- — I (S) $3500
- — Z (S) $5500
1910.119 J04 III
- Issued
- Mar 4, 2014
- Abate by
- Apr 6, 2014
- Penalty
- Initial $5,500 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.119(j)(4)(iii): The frequency of inspections and tests of process equipment was not consistent with applicable manufacturers' recommendations and good engineering practices, and more frequently if determined to be necessary by prior operating experience: 1987 Freezer/Dairy Anhydrous Ammonia Detection System - The employer did not establish a frequency for calibrating the ammonia gas detectors.
Recent events (2)
- — I (S) $3500
- — Z (S) $5500
1910.178 A05
- Issued
- Mar 4, 2014
- Abate by
- Mar 8, 2014
- Penalty
- Initial $5,500 · Current $5,500
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments, the approximate weight of the truck and attachment combination, and the capacity of the truck and attachment combination at maximum elevation with load laterally centered: Frozen Food, Battery Charging Room - The Crown model RC5545-40 lift truck, serial number 1A343231, was not provided with a capacity data plate corresponding to the layer picker attachment manufactured by Tygard Machine & Manufacturing Company.
Recent events (2)
- — I (S) $5500
- — Z (S) $5500
1910.23 C01
- Issued
- Mar 4, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $27,500 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): 1987 Freezer/Dairy Building, North end of Condenser #4 - Employees walking on the designated walkway were exposed to a fall hazard from the roof's unprotected edge to the ground below. Hannaford Brothers Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.132(a), which was contained in OSHA inspection number 315298265, citation number 1, item number 1 and was affirmed as a final order on 7/22/11, with respect to a workplace located at 22 Fitchburg Road, Ayer, Massachusetts.
Recent events (2)
- — I (S) $7000
- — Z (R) $27500
1910.119 F03
- Issued
- Mar 4, 2014
- Abate by
- Apr 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(3): The employer did not annually certify that operating procedures were current and accurate: Establishment - The employer did not certify that operating procedures were current and accurate for the years 2012 and 2013.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.119 J04 IV
- Issued
- Mar 4, 2014
- Abate by
- Apr 6, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that had been performed on process equipment. The documentation did not identify the date of the inpsection or test, the name of the person who performed the inspection or test, the serial number or other identifier of the equipment on which the inspection or test was performed, a description of the inspection or test performed, and the results of the inspection or test: 1987 Freezer/Dairy Anhydrous Ammonia Refrigeration System - The last documented calibration of Honeywell electrochemical gas sensors was 12/20/12. Honeywell performed that calibration and created that document which specified a calibration due date of 6/20/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Hannaford Brothers Distribution Center 01
View Hannaford Brothers Distribution Center 01's full OSHA safety record →