Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: VICTORY BLUE LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VICTORY BLUE LLC in 2101 TERMINAL ROAD, FORT WORTH, TX 76106 (NAICS 424690). OSHA activity number 339555716.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Victory Blue LLC for free Get an email when a new federal OSHA severe-injury report for Victory Blue LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VICTORY BLUE LLC
Site address
2101 TERMINAL ROAD
City
FORT WORTH
State
TX
ZIP
76106
Mailing
2101 TERMINAL RD., FORT WORTH, TX 76106
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424690
Employees
13
Ownership type
Private (A)

6 citations on file for this inspection.

1910.26 C02 VII

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 26, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked and taken out of service until repaired.   On or about January 17, 2014 and times prior thereto, the employer did not ensure ladders with defects were removed from service. Employees who worked in the Urea Batch Mixing Department used a 16 foot Werner extension ladder with a broken rung exposing employees to fall hazards.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.134 C02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 26, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  On or about January 17, 2014, and times prior thereto, employees were not medically fit tested or trained in the proper use and care of air purifying respirators provided by the employer for their use.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.134 K06

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 26, 2014
Abate by
Jul 25, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:(1910.134(c)(2)(ii):  On or about January 17, 2014, and times prior thereto, the employer did not provide employees who used 3M Air Purifying Respirators with the basic information of Appendix D exposing employees to respiratory illnesses or health effects.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 Q01

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 26, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  On or about January 17, 2014, and times prior thereto, the employer did not ensure that forklifts were maintained in a safe condition. Employees were required to operate forklifts in an unsafe condition exposing employees to struck by hazards.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jun 26, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):   On or about January 17, 2014, and times prior thereto, in the Urea Mixing Department, the Urea Batch Mixing Auger was not fully guarded exposing employees to caught in and/or amputation hazards.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1910.305 B02 I

Serious Gravity 5 3 instances 4 exposed
Issued
Jun 26, 2014
Abate by
Jul 25, 2014
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about January 17, 2014, and times prior thereto, the employer did not ensure all pull boxes, and junction boxes were provided with covers exposing employees to electrical shock hazards:   1.  The electrical junction box located on the wall by the Roytronic Metering Pump Anti Scalant station did not have a cover.  2.  Conduit located by the door on the east side of the building that exited to rail dump pit was not provided with a cover.  3.  An electrical box located on the west wall of the production area where employees turn on the lighting of   the production area did not have a cover.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339555716.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.