Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOERNER DISTRIBUTOR, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KOERNER DISTRIBUTOR, INC. in 1305 W. WABASH AVE., EFFINGHAM, IL 62401 (NAICS 424810). OSHA activity number 339556532.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Koerner Distributor, INC. — free Get an email when a new federal OSHA severe-injury report for Koerner Distributor, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1305 W. WABASH AVE.
City
EFFINGHAM
State
IL
ZIP
62401
Mailing
1305 W. WABASH, EFFINGHAM, IL 62401
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424810
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2014
Abate by
Mar 26, 2014
Penalty
Initial $3,240 · Current $2,268 Reduced
29 CFR 1910.132(a):  Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:      Employees performing manual battery filling operations were exposed to acid splash contact burns and the employer did not provide the personal protective equipment including, but not necessarily limited to, sealing eyewear, face shield, chemical resistant gloves, sleeves, and chemical resistant splash smock that were necessary to prevent injury.
Recent events (2)
  • — I (S) $2268
  • — Z (S) $3240

1910.133 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): Protective face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:     Employees performing manual battery filling operations were exposed to acid splash contact burns and the employer did not provide the eye and face protection equipment necessary to prevent injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2014
Abate by
Mar 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(3)(i): Powered industrial truck operators did not receive initial training in vehicle [J] inspection and maintenance and [K] refueling and recharging of batteries:    Employees performing manual battery filling operations were exposed to acid splash contact burns and the employer did not provide training to forklift operation personnel regarding the personal protective equipment necessary to prevent injury during maintenance operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2014
Abate by
Mar 26, 2014
Penalty
Initial $3,240 · Current $0 Reduced
29 CFR 1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    Employees performing manual battery filling operations were exposed to acid splash contact burns and the employer did not ensure clear walkway access to the eyewash intended to serve the battery watering area for immediate emergency use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3240

1910.303 G01 I A

Other-than-serious 1 instance 4 exposed
Issued
Mar 14, 2014
Penalty
Initial $2,430 · Current $0 Reduced
29 CFR 1910.303(g)(1)(i)[A]:  The dimension of the working space in the direction of access to live parts operating at 600 volts or less and likely to require examination, adjustment, servicing, or maintenance while alive was less than indicated in Table S-1:      Employees working in the area of the liquor beverages electrical panelboard were exposed to electrical hazards and the employer did not ensure the working space in front of the electrical panel was at least 36 inches as indicated in Table S-1.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2430

View Koerner Distributor, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339556532.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.