Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OBERG INDUSTRIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OBERG INDUSTRIES in 2301 SILVERVILLE ROAD, FREEPORT, PA 16229 (NAICS 333514). OSHA activity number 339557225.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oberg Industries — free Get an email when a new federal OSHA severe-injury report for Oberg Industries is published. One employer, no account, unsubscribe in one click.
Establishment
OBERG INDUSTRIES
Site address
2301 SILVERVILLE ROAD
City
FREEPORT
State
PA
ZIP
16229
Mailing
2301 SILVERVILLE ROAD, FREEPORT, PA 16229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333514
Employees
400
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 10, 2014
Abate by
Mar 7, 2014
Penalty
Initial $2,550 · Current $1,658 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:     (a) Facility, EDM Wire Cut Area: On or before January 22, 2014, an employee did not use equipment specific written procedures to isolate the equipment from its energy sources.
Recent events (2)
  • — I (S) $1658
  • — Z (S) $2550

1910.147 C07 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 10, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:   (a) Facility, EDM Wire Cut Area: On or before 1-22-14, equipment operators working to service or maintain the equipment were not trained to an authorized level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 10, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:   (a) Facility, EDM Wire Cut Area: On or before 1-22-14, an employee did not apply energy isolating devices to previously identified energy sources prior to performing service and/or maintenance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 10, 2014
Penalty
Initial $2,550 · Current $1,658 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     (a) Facility, Polishing Area: On or before January 22, 2014, an employee was exposed to laceration hazards in that a lathe was operated with its chuck unguarded against incidental contact while polishing parts.
Recent events (2)
  • — I (S) $1658
  • — Z (S) $2550

1910.333 C10

Serious Gravity 1 4 instances 4 exposed
Issued
Feb 10, 2014
Penalty
Initial $2,550 · Current $1,658 Reduced
29 CFR 1910.333(c)(10): A person not qualified defeated an electrical safety interlock:     (a) Facility, Container Tooling Department, Mori Seiki SL25 CNC Lathe: On or before January 22, 2014, the machine was operating in a production mode while its interlock remained by-passed.       (b) Facility, Container Tooling Department, Kellenberger Kel-Viva Universal CNC Grinding Machine A: On or before January 22, 2014, the machine was operating in a production mode while its interlock remained by-passed.       (c) Facility, Container Tooling Department, Kellenberger Kel-Viva Universal CNC Grinding Machine B: On or before January 22, 2014, the machine was operating in a production mode while its interlock remained by-passed.     (d) Facility, Container Tooling Department, Kellenberger Kel-Varia Universal CNC Grinding Machine: On or before January 22, 2014, the machine was operating in a production mode while its interlock remained by-passed.
Recent events (2)
  • — I (S) $1658
  • — Z (S) $2550

1910.213 B03

Other-than-serious 1 instance 1 exposed
Issued
Feb 10, 2014
Abate by
Mar 7, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:   (a) Facility, Shipping and Receiving: On or before January 22, 2014, a radial arm saw used for cutting wood was not equipped with a device to protect against its unexpected startup in the event of a power outage.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Oberg Industries's full OSHA safety record →