Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: FLEX ELECTRICAL CONSTRUCTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FLEX ELECTRICAL CONSTRUCTORS, INC. in UNITY HOUSE 2431 6TH AVENUE, TROY, NY 12180 (NAICS 238210). OSHA activity number 339559189.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flex Electrical Constructors, INC. for free Get an email when a new federal OSHA severe-injury report for Flex Electrical Constructors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
UNITY HOUSE 2431 6TH AVENUE
City
TROY
State
NY
ZIP
12180
Mailing
2431 3RD AVENUE, WATERVLIET, NY 12189
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
25
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    a)  During electrical work on or before 1/22/14 employees were not instructed in the recognition and avoidance of arc flash hazards associated with 480 volt electrical panels and related equipment.
Recent events (2)
  • · I (O) $2400
  • · Z (S) $2400

1926.95 A

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact.    a)  During electrical work, on or before January 22, 2014.  The personal protective gear being worn by the employee, safety glasses and insulated gloves, was not adequate personal protective equipment while performing preparation work for installing a new 60 amp 3 pole breaker in an existing 480 volt electrical panel in that the personal protective equipment used by the employee did not provide adequate protection from arc flash hazards when working on an energized panel.
Recent events (2)
  • · I (O) $2400
  • · Z (S) $2400

1926.301 A

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 15, 2014
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.301(a): Employers shall not issue or permit the use of unsafe hand tools.    a)  On or about January 22, 2013 an employee was permitted to use a unsafe hand tool (utility knife wrappped with electrical tape) in an energized panel.
Recent events (2)
  • · I (O) $2400
  • · Z (S) $2400

1926.416 A01

Other-than-serious 1 instance 2 exposed
Issued
Apr 3, 2014
Abate by
Apr 22, 2014
Penalty
Initial $2,400 · Current $2,400
29 CFR 1926.416(a)(1): No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.    a)  On or before January 22, 2014 electrical work involving a 480 volt electrical panel was being conducted with the conductors energized while an employee was exposed to possible contact while attempting to complete preparation work for installation of a 60 Amp 3 pole breaker in the electrical panel.
Recent events (2)
  • · I (O) $2400
  • · Z (S) $2400

View Flex Electrical Constructors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339559189.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.