Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BROUGHTON FOODS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BROUGHTON FOODS in 1701 GREENE STREET, MARIETTA, OH 45750 (NAICS 311511). OSHA activity number 339560401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Broughton Foods — free Get an email when a new federal OSHA severe-injury report for Broughton Foods is published. One employer, no account, unsubscribe in one click.
Establishment
BROUGHTON FOODS
Site address
1701 GREENE STREET
City
MARIETTA
State
OH
ZIP
45750
Mailing
1701 GREENE STREET, MARIETTA, OH 45750
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311511
Employees
90
Ownership type
A

4 citations on file for this inspection.

1910.219 C02 I

Serious Gravity 5 2 instances 3 exposed
Issued
Feb 26, 2014
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.  a. At the worksite located in Marietta, Ohio the employer had an Industrial Electric Motor on the floor that had horizontal shafting that was not properly guarded.  The motor was located next to the A-side cleaning tank in the processing room.  b. At the worksite located in Marietta, Ohio the employer had an Industrial Electric Motor on the floor that had horizontal shafting that was not properly guarded.  The motor was located next to the B-side cleaning tank in the processing room.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.303 G02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 26, 2014
Abate by
Apr 2, 2014
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidentalcontact by use of approved cabinets or other forms of approved enclosures or by any of the following means:  a. At the site located in Marietta, Ohio the employer had employees that were exposed to live electrical, operating at approximately 220 VAC, when they opened an electrical box in the processing room in order to reset a conveyor belt.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.305 B02 I

Serious Gravity 5 2 instances 7 exposed
Issued
Feb 26, 2014
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.  a. At the site located in Marietta, Ohio the employer had a faceplate missing on an outlet box for electrical wire on the table where the milk jugs were placed in the de-bag area.  b. At the site located in Marietta, Ohio the employer had a missing cover on a junction box underneath a panel board in the blow mold area.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

1910.305 J02 IV

Serious Gravity 5 2 instances 7 exposed
Issued
Feb 26, 2014
Penalty
Initial $4,250 · Current $2,550 Reduced
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location shall be suitable for the location.  a. At the site located in Marietta, Ohio the employer had a receptacle in the processing room that was missing its cover to protect it from the clean-up operations that used a garden hose and sprayer.  b. At the site located in Marietta, Ohio the emploiyer had a receptacle in the hallway by the iodine hose and mix vat that was missing its cover to protect it from the clean-up operations that used a garden hose and sprayer.
Recent events (2)
  • — I (S) $2550
  • — Z (S) $4250

View Broughton Foods's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339560401.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.