OSHA Inspection: EDUARD CRUZ MASONRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EDUARD CRUZ MASONRY in 350 W CEDAR STREET, PENSACOLA, FL 32507 (NAICS 238140). OSHA activity number 339560922.

Watch Eduard Cruz Masonry — free Get an email when a new federal OSHA severe-injury report for Eduard Cruz Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
EDUARD CRUZ MASONRY
Site address
350 W CEDAR STREET
City
PENSACOLA
State
FL
ZIP
32507
Mailing
230 TOWN LANE, FAYETTEVILLE, GA 30214
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  a.  On or about January 14, 2014, on the 3rd floor deck, the north and west side scaffold platforms were not fully planked or decked between the front uprights and the guardrail supports, exposing employees to a 25 feet fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a.  On or about January 14, 2014, on the 3rd floor deck, the north side scaffold platform did not have a guardrail, exposing an employee to a 25 feet fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.451 G04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms:  a.  On or about January 14, 2014, on the 3rd floor, the north, west, and east side scaffold platforms did not have a guardrail system along all open sides and ends of the platforms, exposing an employee to a 25 feet fall hazard.
Recent events (1)
  • — Z (S) $2800

1926.502 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high:  a.  On or about January 14, 2014, on the 3rd floor, the north and west side scaffold platforms did not have midrails, exposing an employee to a 25 feet fall hazard.
Recent events (1)
  • — Z (S) $1700

1926.1053 A24

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $2000.00
29 CFR 1926.1053(a)(24): The side rails of through or sidestep fixed ladders did not extend 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder:  a.  On or about January 14, 2014, on the west side of the building at the ground level, the fixed ladder on the scaffold did not extend 42 inches above the access level, exposing employees to a 13 feet fall hazard.
Recent events (1)
  • — Z (S) $2000

1926.1053 B05 I

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $1700.00 · Current $1700.00
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  a.  On or about January 14, 2014, on the west side of the building, the ladder used to access the 2nd floor was not angled correctly, exposing employees to a 14 feet fall hazard.
Recent events (1)
  • — Z (S) $1700