MARIANNA, FL —
OSHA Inspection: ROLLS RITE TRAILERS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ROLLS RITE TRAILERS, INC. in 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL 32446 (NAICS 336214). OSHA activity number 339564049.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROLLS RITE TRAILERS, INC.
- Site address
- 3741 INDUSTRIAL PARK DRIVE
- City
- MARIANNA
- State
- FL
- ZIP
- 32446
- Mailing
- 3741 INDUSTRIAL PARK DRIVE, MARIANNA, FL 32446
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336214
- Employees
- 16
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.107 C06
- Issued
- Apr 11, 2014
- Abate by
- May 7, 2014
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: a. On or about January 28, 2014, a wall mounted electrical receptacle box in the spray room used to the power the airless spray painting pump was within 10 feet of the spraying area, exposing the employee to fire hazards. b. On or about January 28, 2014, the fluorescent lights in the spray room were within 13 feet 10 inches of the spraying area, exposing the employee to fire hazards.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.134 C01 III
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $2,800 · Current $1,100 Reduced
0527
General-duty citation text
29 CFR 1910.134(c)(1)(iii): The written program did not contain fit test procedures for tight-fitting respirators: a. On or about February 11, 2014, the spray painter wore a half-face respirator and the employer's written respiratory protection program did not address fit testing procedures.
Recent events (2)
- — I (S) $1100
- — Z (S) $2800
1910.134 E01
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
0527
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or used the respirator in the workplace: a. On or about February 11, 2014, an employee who wore a half-face respirator had not been provided with a medical evaluation prior to wearing the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F01
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
0527
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a. On or about February 11, 2014, an employee who wore a half-face respirator had not been fit tested prior to initial use of the respirator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K03
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
0527
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to employees using a respirator in the workplace: a. On or about February 11, 2014, an employee who wore a half-face respirator had not received respirator training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1000 A02
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
0527
General-duty citation text
29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Carbon Black listed in Table Z-1 in excess of the 8 hour Time Weighted Average (TWA) concentration of 3.5 milligrams per cubic meter (mg/m3): a. An employee spray painting metal trailers was exposed to Carbon Black at a TWA of 5.4 mg/m3, 1.6 times the permissble exposure limit of 3.5 mg/m3. The sampling was performed during one shift on February 11, 2014, for 165 minutes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C04
- Issued
- Apr 11, 2014
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: a. On or about January 28, 2014, the employer did not ensure that fire extinguishers provided for employees use in the event of a fire were fully charged and in operable condition because all of the fire extinguishers throughout the facility had not been inspected since September 2009, exposing employees to fire hazards.
Recent events (2)
- — I (S) $1000
- — Z (S) $1200
1910.252 B02 III
- Issued
- Apr 11, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a. On or about January 28, 2014, employees working next to welding areas were not protected from welding rays.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1910.253 B04 III
- Issued
- Apr 11, 2014
- Penalty
- Initial $2,000 · Current $1,100 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. On or about January 28, 2014, bottle storage area, oxygen and acetylene cylinders were stored within 9 feet of each other and were not separated by a noncombustible barrier.
Recent events (2)
- — I (S) $1100
- — Z (S) $2000
1910.1200 E01
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $2,800 · Current $1,100 Reduced
0527
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a. On or about January 28, 2014, the employer did not develop and implement the written hazard communication program which described how requirements of 29 CFR 1910.1200(f), (g), and (h) would be met for employees who have exposure to hazardous materials such as but not limited to ethyl benzene, xylene, carbon black, oxygen, and acetylene.
Recent events (2)
- — I (S) $1100
- — Z (S) $2800
1910.1200 H01
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
0527
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a. On or about January 28, 2014, the employer did not provide information and training to employees who had exposure to hazardous materials such as but not limited to ethyl benzene, xylene, carbon black, oxygen, and acetylene.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H03 IV
- Issued
- Apr 11, 2014
- Abate by
- Jun 2, 2014
- Penalty
- Initial $0 · Current $0
0527
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a. On or about January 28, 2014, the employer did not include in the hazard communication program an explanation of the labeling system, safety data sheet, and training to employees who have exposure to hazardous materials such as but not limited to ethyl benzene, xylene, carbon black, oxygen, and acetylene.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Apr 11, 2014
- Abate by
- May 7, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a. On or about January 28, 2014, employees that operated powered industrial trucks throughout the workplace were not provided the required training and evaluation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Rolls Rite Trailers, INC.
View Rolls Rite Trailers, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336214)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339564049.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.