MINOCQUA, WI —
OSHA Inspection: EVANS AUTOMOTIVE ENTERPRISES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of EVANS AUTOMOTIVE ENTERPRISES, INC. in 9736 RAY PLACE, MINOCQUA, WI 54548 (NAICS 811191). OSHA activity number 339564809.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EVANS AUTOMOTIVE ENTERPRISES, INC.
- Site address
- 9736 RAY PLACE
- City
- MINOCQUA
- State
- WI
- ZIP
- 54548
- Mailing
- 9736 RAY PLACE, MINOCQUA, WI 54548
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811191
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 A08 II
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons could accidentally walk were not guarded by a floor hole cover of standard strength and construction: On and before 1/27/14, the two oil change pits were not equipped with covers or nets to prevent employees from falling into the pits.
Recent events (1)
- — Z (S) $0
1910.133 A01
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On and before 1/27/14, employees performing oil changes and other automotive repair work were not provided with safety glasses and/or face shields to protect them from chemical splashes, falling rust or other road debris, or from flying sparks or objects from the bench grinder.
Recent events (1)
- — Z (S) $0
1910.215 B09
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: On and before 1/27/14, the pedestal mounted bench grinder was not equipped with a tongue guard to reduce the likelihood of employees being struck by a piece of a disintegrating abrasive wheel.
Recent events (1)
- — Z (S) $0
1910.242 B
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On and before 1/27/14, a compressed air blower nozzle was connected to an airline without a regulator to reduce the pressure to less than 30 psi.
Recent events (1)
- — Z (S) $0
1910.303 G02 I
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On and before 1/27/14, employees were exposed to electrical hazards from a parts washer machine that has its cord spliced and with the switches not enclosed and secured in a box. The live terminal screws on the switches were not covered with an approved insulating material to prevent contact by employees.
Recent events (1)
- — Z (S) $0
1910.305 B02 I
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: On and before 1/27/14, employees were exposed to shock hazards from an electrical outlet box that did not have a cover plate.
Recent events (1)
- — Z (S) $0
1910.1200 G08
- Issued
- Feb 27, 2014
- Abate by
- Mar 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: On and before 1/27/14, employees did not know where the MSDSs were kept in the building.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 811191)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339564809.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.