Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: COL-G FITNESS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COL-G FITNESS, INC. in 250 KENNEDY DRIVE, HAUPPAUGE, NY 11749 (NAICS 423910). OSHA activity number 339565681.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Col-G Fitness, INC. for free Get an email when a new federal OSHA severe-injury report for Col-G Fitness, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
COL-G FITNESS, INC.
Site address
250 KENNEDY DRIVE
City
HAUPPAUGE
State
NY
ZIP
11749
Mailing
250 KENNEDY DRIVE, HAUPPAUGE, NY 11749
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423910
Employees
18
Ownership type
Private (A)

4 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 3 instances 8 exposed
Issued
Jul 18, 2014
Abate by
Sep 4, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Workplace, in warehouse- a DeWalt Palm Sander was plugged into a metal quad outlet box that was not mounted to a wall, beam, etc.. The quad box was not used in accordance with manufacturer instructions; on or about 1/28/14.    b) Workplace, in warehouse- a Global Electric Pedestal Fan was plugged into a metal quad outlet box that was not mounted to a wall, beam, etc.. The quad box was not used in accordance with manufacturer instructions; on or about 1/28/14.    c) Workplace, in warehouse- a dual receptacle outlet box was not mounted to a wall, beam etc.. The box was not used in accordance with manufacturer instructions; on or about 1/28/14.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1910.304 F01 IV

Serious Gravity 5 3 instances 8 exposed
Issued
Jul 18, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:    a) Workplace, west wall of warehouse area- Breaker box used to provide power for workplace lights, fans and hand tools was blocked by two wooden tables. Tables had several pieces of unused fitness equipment on top of and one metal ladder leaning against them; on or about 1/28/14.    b) Workplace, west wall of warehouse area- Breaker box used to provide power for workplace lights, fans and hand tools was blocked by two wooden tables. Tables had several pieces of unused fitness equipment on top of and one metal ladder leaning against them; on or about 1/28/14.    c) Workplace, west wall of warehouse area- Breaker box used to provide power for workplace lights, fans and hand tools was blocked by two wooden tables. Tables had several pieces of unused fitness equipment on top of and one metal ladder leaning against them; on or about 1/28/14.    Note:  Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1910.305 B02 I

Serious Gravity 5 2 instances 8 exposed
Issued
Jul 18, 2014
Abate by
Aug 21, 2014
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:    a) Warehouse, Technician's work area- a De Walt Palm Sander and a Cybex Treadmill were plugged into a pendant outlet that did not have a cover plate thereby exposing energized parts; on or about 1/28/14.    b) Warehouse, Technician's work area- a pendant outlet that did not have a cover plate was used throughout the day by Technician's plugging in their hand tools thereby exposing Technicians to energized parts; on or about 1/28/14    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • · I (S) $1400
  • · Z (S) $2000

1904.40 A

Other-than-serious 2 instances 18 exposed
Issued
Jul 18, 2014
Abate by
Aug 1, 2014
Penalty
Initial $0 · Current $0
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.  a) Workplace- OSHA 300 logs were requested for the previous five years, 2013, 2012, 2011, 2010 and 2009. Records were not produced on 1/30/14.  b) Workplace- OSHA 300 logs were requested for the previous five years, 2013, 2012, 2011, 2010 and 2009. Records were not produced on 7/7/14.  Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339565681.