Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C AND D AUTOMATION & MACHINE CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C AND D AUTOMATION & MACHINE CO., INC. in 20 INDUSTRIAL DRIVE, OXFORD, AL 36203 (NAICS 332710). OSHA activity number 339567901.

Watch C AND D Automation & Machine CO., INC. — free Get an email when a new federal OSHA severe-injury report for C AND D Automation & Machine CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
20 INDUSTRIAL DRIVE
City
OXFORD
State
AL
ZIP
36203
Mailing
20 INDUSTRIAL DRIVE, OXFORD, AL 36203
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
13
Ownership type
A

8 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   a) On or about 01/23/2014 - Shop floor, a lockout / tagout program had not been established for employees that perform servicing, maintenance, or cleaning on equipment such as, but no limited to, the FADAL 40/20 CNC machines.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1200.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a) On or about 01/23/2014 - Shop floor, employees operating a Jet Pit powered industrial truck had not been trained and evaluated.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.212 A01

Serious Gravity 10 6 instances 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) On or about 01/23/2014 - Vertical milling machine department, a Clausing vertical milling machine, Model FV-1, S/N# U-539 was being operated with unguarded rotating parts.   b) On or about 01/23/2014 - Vertical milling machine department, a Clausing vertical milling machine, Model FV-1, S/N# U5-40 was being operated with unguarded rotating parts,   c) On or about 01/23/2014 - Lathe department, a Birmingham horizontal lathe, Model TX-170 was being operated with unguarded rotating parts.   d) On or about 01/23/2014 - Lathe department, a Victor lathe (No Model# or S/N# could be identified) was being operated with unguarded rotating parts.   e) On or about 01/23/2014 - Lathe department, MSC 18-80G Gap lathe, S/N#2JPOL48 was being operated with unguarded rotating parts.   f) On or about 01/23/2014 - Cutting department, an ENCO-450 band saw was being operated with the unused portion of the blade unguarded.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.219 E01 I

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  a) On or about 01/23/2014 - Vertical milling department, a Clausing Kondin Model FV-1, S/N U-539 had a horizontal belt that was not guarded.   b) On or about 01/23/2014 - Vertical milling department, a Clausing Kondin Model FV-1, S/N U-540 had a horizontal belt that was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $960.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:  a) On or about 01/23/2014 - Shop floor, the Rockwell abrasive wheel, Model#23-750, the work rest exceeded the requirement by 11/16 inch.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:   a) On or about 01/23/2014 - Shop floor, the Rockwell abrasive wheel, Model#23-750, the tongue guard exceeded the requirement by 3/8 inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $720.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a) On or about 01/23/2014 - Shop floor, compressed air was used with an output of 50 p.s.i. while cleaning.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.303 G01

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   a) On or about 01/23/2014 - Shop floor, an air compressor, manual lathe, and miscellaneous material were being stored in front of electrical panels.    b) On or about 01/23/2014 - Shop floor, a pile of miscellaneous equipment and materials was being stored in front of an electrical panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339567901.