Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MUZA SHEETMETAL COMPANY LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MUZA SHEETMETAL COMPANY LLC in 51 W. FERNAU AVE, OSHKOSH, WI 54901 (NAICS 238390). OSHA activity number 339569097.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Muza Sheetmetal Company LLC — free Get an email when a new federal OSHA severe-injury report for Muza Sheetmetal Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
51 W. FERNAU AVE
City
OSHKOSH
State
WI
ZIP
54901
Mailing
51 W. FERNAU AVE, OSHKOSH, WI 54901
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
60
Ownership type
A

2 citations on file for this inspection.

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Mar 14, 2014
Abate by
Apr 4, 2014
Penalty
Initial $1,785 · Current $893 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    a)    The company had an employee driving lift truck that was not a certified operator.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $892.5
  • — Z (S) $1785

1910.253 B04 III

Serious Gravity 5 1 instance 20 exposed
Issued
Mar 14, 2014
Abate by
Mar 24, 2014
Penalty
Initial $2,975 · Current $1,488 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a)    Oxygen and acetylene cylinders were stored together out side of the SW corner door.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1487.5
  • — Z (S) $2975

View Muza Sheetmetal Company LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339569097.