OSHA Inspection: SENSORY EFFECTS POWDER SYSTEMS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SENSORY EFFECTS POWDER SYSTEMS, INC. in 111 WEST HIGH STTREET, DEFIANCE, OH 43512 (NAICS 311999). OSHA activity number 339569105.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sensory Effects Powder Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Sensory Effects Powder Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
111 WEST HIGH STTREET
City
DEFIANCE
State
OH
ZIP
43512
Mailing
111 WEST HIGH STTREET, DEFIANCE, OH 43512
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
103
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 2 instances 6 exposed
Issued
Jul 16, 2014
Abate by
Nov 26, 2014
Penalty
Initial $7,000 · Current $0 Reduced

Hazardous substances E101M102

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to combustible dust (powdered food ingredients) deflagration, explosion, and/or other fire hazards while working at or near spray drying equipment that was not adequately designed to prevent or minimize employee exposure in the event of an internal deflagration or other fire event:    (a)  Sensory Effects Powder Systems, Inc. located in Defiance, Ohio:  On or about January 31, 2014, the Powder Department's DJ box spray dryer system (main chamber, secondary heating chamber, cooling chamber, drop-out box, and fines recovery cyclones) handling combustible powdered food ingredient dust, operated without a means of explosion protection, including a means to prevent the propagation of a flame front to connected equipment/employee occupied areas:      a.      The dryer lacked a recognized method of explosion protection.      b.     The dryer's drop-out box was open to the downstream shaker table and lacked a method of deflagration propagation prevention (isolation) to downstream operations.   c.      The indoor fines recovery cyclones lacked a method of explosion protection.      (b) Sensory Effects Powder Systems, Inc. located in Defiance, Ohio:  On or about January 31, 2014 the Powder Department building housing the DJ box spray dryer system and open shaker table handling combustible powdered food ingredient dust, lacked a mean of safely relieving pressure from an internal primary deflagration/explosion occurring inside.  Recognized methods of damage limiting construction were not present.   Among other methods, feasible methods to correct this hazard would be to comply with the National Fire Protection Association's (NFPA) Standards NFPA 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Particulate Solids, 2013 ed.) - Sections 6.4.1, 7.1.4.1, 7.1.6.1, 7.1.7, 7.13.1.1.1, 7.18.6, 7.18.8; NFPA 61 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities, 2013 ed. Sections 4.1.2, 6.2.1, 6.3, 8.3.4, 10.4.3; and NFPA 86 Standard for Ovens and Furnaces, 2011 ed. Section 5.3.1.   Specifically, (1) provide spray dryers and associated fines recovery cyclones with a recognized method of explosion protection such as deflagration venting to a safe outdoor location in accordance with NFPA 68 Standard on Explosion Protection by Deflagration Venting or chemical deflagration suppression in accordance with NFPA 69 Standard on Explosion Prevention Systems; (2) provide the connection between the spray dryer's drop-out box and the shaker table with a recognized method of isolation such as passive isolation via a material choke (rotary valve) per the design requirements in NFPA 69; (3) provide damage limiting construction elements within the structural components of the building such as deflagration venting (engineered relief panels) discharging to safe outdoor locations and in accordance with NFPA 68.
Recent events (3)
  • — J (S) $0
  • — C (S) $7000
  • — Z (S) $7000

5(a)(1)

Deleted Serious Gravity 5 1 instance 6 exposed
Issued
Jul 16, 2014
Abate by
Nov 26, 2014
Penalty
Initial $5,000 · Current $0 Reduced

Hazardous substances E101M102

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to combustible dust (powdered food ingredients)  deflagration, explosion, and/or other fire hazards while working at or near a fabric filter media-type dust collector that was not adequately designed and located to prevent or minimize employee exposure in the event of an internal deflagration or other fire event:  (a)  Sensory Effects Powder Systems, Inc. located in Defiance, Ohio:  On or about January 31, 2014,  a fabric filter media-type (baghouse) dust collector  located adjacent to the Powder Pack Department and handling combustible powdered food ingredient dust,  operated without a means of explosion protection including deflagration propagation protection (isolation) to upstream processing areas.  In addition, the dust collector recycled exhaust air directly back into the building.  Among other methods, feasible methods to correct this hazard would be to comply with the National Fire Protection Associations (NFPA) Standards NFPA 654 Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Particulate Solids, 2013 ed.) - Sections 7.1.4.1, 7.13.1.1.1, 7.13.1.6.1, 7.1.6.1, 7.1.7; and NFPA 61 Standard for the Prevention of Fires and Dust Explosions in Agricultural and Food Processing Facilities, 2013 ed.  Sections 6.3, 10.4.3, 10.4.12.1.  Specifically, (1) relocate the dust collector outside and provide it with a recognized method of explosion protection such as deflagration venting to a safe location in accordance with NFPA 68 Standard on Explosion Protection by Deflagration Venting or equip indoor dust collectors with a recognized method of explosion protection such as deflagration venting to a safe outdoor location in accordance with NFPA 68 or chemical deflagration suppression in accordance with NFPA 69 Standard on Explosion Prevention Systems; (2) isolate the dust collector from the upstream process via the use of an active or passive deflagration isolation system in accordance with NFPA 69; (3) prohibit the recycling of dust collector exhaust into indoor locations unless the requirements listed in NFPA 654 Section 7.13.1.6.3 can be met.
Recent events (3)
  • — J (S) $0
  • — C (S) $5000
  • — Z (S) $5000

1910.132 D02

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 16, 2014
Abate by
Aug 15, 2015
Penalty
Initial $7,000 · Current $7,000

Hazardous substances E101M102

originally issued as   29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    (a) Sensory Effects Powder Systems, Inc. located in Defiance, Ohio: On or about January 31, 2014, the employer did not ensure employees working around the DJ Dryer located in the Powder Department were wearing flame retardant clothing when exposed to fire hazards from the ignition of combustible dusts.    PER FSA MODIFIED TO:  29 CFR 1910.132(d)(2):  The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated:    a) The employer did not certify through a written document that it had completed the hazard assessment within the previous year.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.307 C02 I

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 16, 2014
Abate by
Aug 1, 2014
Penalty
Initial $6,000 · Current $6,000

Hazardous substances E101

29 CFR 1910.307(c)(2)(i): Equipment was not approved not only for the class of location, but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that would be present.     (a) Sensory Effects Powder Systems, Inc. located in Defiance, Ohio:  On or about January 31, 2014, the employer did not ensure electrical equipment such as but not limited to the DJ Dryer control panel located in the Powder Department were approved for operation in a hazardous environment.    amended to: The employer did not ensure the electrical panel approved for operation in the area had all bolts installed to secure and seal the back panel.
Recent events (3)
  • — J (S) $6000
  • — C (S) $6000
  • — Z (S) $6000

1910.145 C03

Other-than-serious 1 instance 6 exposed
Issued
Jul 16, 2014
Abate by
Sep 21, 2015
Penalty
Initial $0 · Current $0

Hazardous substances E101M102

29 CFR 1910.145(c)(3): Safety instruction signs were not used where there was a need for general instructions and suggestions relative to safety measures.    (a) Sensory Effects Powder Systems, Inc. located in Defiance, Ohio:  On or about January 31, 2014, the employer did not ensure safety warning signs were posted in the Powder Department informing employees of the hazards of combustible dusts.