OSHA Inspection: DETWILER ROOFING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DETWILER ROOFING in 121 PEMBROKE COURT, EXTON, PA 19341 (NAICS 238160). OSHA activity number 339570681.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Detwiler Roofing for free Get an email when a new federal OSHA severe-injury report for Detwiler Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
DETWILER ROOFING
Site address
121 PEMBROKE COURT
City
EXTON
State
PA
ZIP
19341
Mailing
324 LINDEN GROVE ROAD, NEW HOLLAND, PA 17557
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B11

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 19, 2014
Abate by
Mar 25, 2014
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) Jobsite: 121 Pembroke Court, Roof - Employees installing roof shingles on a steep roof (more than 4 in 12) were exposed to fall hazards of approximately twenty (20) feet without the use of guardrail systems with toeboards, safety net systems, or personal fall arrest systems. Observed on or about 10/31/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.1053 B01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Mar 19, 2014
Abate by
Mar 25, 2014
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access.  (a) Jobsite: 121 Pembroke Ct., Roof - The portable extension ladder used to access the roof did not extend at least three (3) feet above the upper landing surface exposing employees to a fall hazard during access and/or egress from the roof.  Employees were installing a new roof approximately twenty (20) feet above the ground.  Observed on or about 10/31/13.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

View Detwiler Roofing's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339570681.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.