GRAND JUNCTION, CO ·
OSHA Inspection: REYNALDO MANCINAS STUCCO
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of REYNALDO MANCINAS STUCCO in 488 SPOON COURT, GRAND JUNCTION, CO 81507 (NAICS 236115). OSHA activity number 339572869.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REYNALDO MANCINAS STUCCO
- Site address
- 488 SPOON COURT
- City
- GRAND JUNCTION
- State
- CO
- ZIP
- 81507
- Mailing
- 3148 BROWNIE CIRCLE, GRAND JUNCTION, CO 81504
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C02
- Issued
- Mar 27, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $1,020 · Current $600 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) Reynaldo Mancinas Stucco at 488 Spoon Court in Grand Junction, CO 81507 : On or before January 29, 2014 the exposing/creating employer in charge of erecting the scaffolding at the worksite did not ensure that all supporting poles had a firm foundation, such as base plates and/or mud sills. This condition exposed employees to fall and struck-by hazards.
Recent events (2)
- · I (S) $600
- · Z (S) $1020
1926.451 B01
- Issued
- Mar 27, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $1,020 · Current $600 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports. a) Reynaldo Mancinas Stucco at 488 Spoon Court in Grand Junction, CO 81507 : On or before January 29, 2014 the exposing/creating employer did not ensure the scaffolding used to perform stucco work was fully planked so as to prevent employees from stepping through or falling from the scaffold. This condition exposed employees to fall hazards.
Recent events (2)
- · I (S) $600
- · Z (S) $1020
1926.451 B03
- Issued
- Mar 27, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(3): Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. a) Reynaldo Mancinas Stucco at 488 Spoon Court in Grand Junction, CO 81507 : On or before January 29, 2014 the exposing/creating employer did not ensure the front edge of the working platform was no more than 14 inches from the face of the work in that measurements indicated the front edge was at least 16 inches from the face of the work. This condition exposed employees to fall hazards to the inside of the scaffold.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 F07
- Issued
- Mar 27, 2014
- Abate by
- Apr 16, 2014
- Penalty
- Initial $1,020 · Current $600 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person: a) Reynoldo Mancinas Stucco at 488 Spoon Court in Grand Junction, CO 81507: On or before January 29, 2014 the exposing/creating employer did not ensure the scaffold used to conduct stucco activities was was erected and/or altered under the supervision of a competent person. Several deficiencies were observed with the scaffold such as but not limited to incomplete planking, missing mud sills, improper distance from the working face. This condition exposed employees to fall and struck-by hazards.