OSHA Inspection: COMPRESSED AIR SYSTEMS, LLC

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of COMPRESSED AIR SYSTEMS, LLC in 2626 SKYWARD DRIVE, GRAND PRAIRIE, TX 75052 (NAICS 332420). OSHA activity number 339573370.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Compressed AIR Systems, LLC for free Get an email when a new federal OSHA severe-injury report for Compressed AIR Systems, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2626 SKYWARD DRIVE
City
GRAND PRAIRIE
State
TX
ZIP
75052
Mailing
2626 SKYWARD DRIVE, GRAND PRAIRIE, TX 75052
Inspection type
Fatality or catastrophe (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
25
Ownership type
Private (A)

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $7,000 · Current $4,550 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards:      On or about February 3, 2014, during the diagnosis/troubleshooting of air compressors, including but not limited to testing for oil leaks in the crankcase, guarding was not provided to protect from crankcase ruptures when pressurizing the system with compressed air.
Recent events (2)
  • · I (S) $4550
  • · Z (S) $7000

1904.39 A

Other-than-serious 1 instance 2 exposed
Issued
Jul 21, 2014
Abate by
Aug 18, 2014
Penalty
Initial $2,000 · Current $1,300 Reduced
29 CFR 1904.39(a): The employer did not orally report the death of an employee or the in-patient hospitalization of three or more employees because of a work-related incident      The violation occurred on January 30, 2014, the employer failed to report to OSHA a work related fatality prior to the elapse of eight (8) hours reporting period of the incident.